摘要

目的 探究假体柄长度对股骨远端肿瘤膝关节假体置换术后假体无菌性松动的影响.方法 选择自2015年6月至2021年6月于四川友谊医院行膝关节假体置换术的164例股骨远端肿瘤患者作为研究对象,根据术后随访2~8年期间假体无菌性松动情况将患者分为未松动组和松动组.未松动组126例,男71例,女55例;年龄25~69岁,平均(47.69±5.48)岁.松动组38例,男24例,女14例;年龄27~70岁,平均(46.12±5.33)岁.比较两组患者的临床资料.采用Kaplan-Meier法分析假体柄长度与假体使用寿命的关系;采用随机森林算法及多因素Logistic回归分析影响患者术后假体无菌性松动的因素;相关性E值法分析研究结果的敏感性;限制性立方样条图分析假体柄长度与患者术后假体无菌性松动的剂量-效应关系;建立预测模型并评价其预测效能.结果 Kaplan-Meier法分析结果显示,假体柄长度与假体使用寿命有关(P<0.001);下肢力线距膝关节中心距离增加是患者术后假体无菌性松动的危险因素(P<0.05),假体柄长度、髓腔柄与股骨直径比值、机械轴股骨远端外侧角、术后髋-膝-踝角增加是保护因素(P<0.05);敏感性分析显示E=2.015;男性患者或女性患者中,假体柄长度与术后假体无菌性松动均不存在非线性关系(P>0.05);当模型预测术后假体无菌性松动概率为0.80时,约登指数最高(77.77),准确度为92.24%,敏感度为85.63%,特异度为92.14%,受试者工作特征曲线下面积为0.825(95%CI:0.766~0.884,P<0.001).结论 下肢力线距膝关节中心距离、假体柄长度、髓腔柄与股骨直径比值等是股骨远端肿瘤患者膝关节假体置换术后假体无菌性松动的影响因素,建议外科医生应选择较长的假体柄和较粗的髓腔柄,增加假体髓腔柄与股骨直径和髓腔直径的贴合度,同时术后应定期检查下肢力线偏倚情况,及时重建下肢力线.

Abstract

Objective To investigate the effect of stem length on aseptic loosening after knee prosthesis replacement for tumors of distal femur.Methods A total of 164 patients with tumors of distal femur who underwent knee prosthesis replacement in Sichuan friendship hospital from June 2015 to June 2021 were selected.According to the aseptic loosening of the prosthesis during the follow-up of 2 to 8 years,the patients were divided into two groups:non-loosening group and loosening group.There were 126 patients in the non-loosening group,71 males and 55 females,aged from 25 to 69 years old,with an average age of(47.69±5.48)years old.There were 38 patients in the loosening group,including 24 males and 14 females,aged from 27 to 70 years old,with an average age of(46.12±5.33)years old.The clinical data of the two groups were compared.Kaplan-Meier method was used to analyze the relationship between the length of the stem and the service life of the prosthesis.Random forest algorithm and multivariate Logistic regression were used to analyze the factors affecting postoperative aseptic loosening of the prosthesis.The sensitivity of the research results was analyzed by correlation E-value method.The dose-effect relationship between the length of prosthesis stalk and postoperative aseptic loosening was analyzed by restriction cubic spline.Establish a prediction model and evaluate its prediction efficiency.Results The results of Kaplan-Meier analysis showed that the length of prosthesis handle was related to the service life of prosthesis(P<0.001).The increase of the distance between the lower limb force line and the center of the knee joint were the risk factors of postoperative aseptic loosening of the prosthesis(P<0.05),the length of the prosthesis,the ratio of the diameter of the medullary stalk to the femur,mechanical lateral distal femoral angle(mLDFA)and the increase of postoperative hip knee ankle angle(HKAA)were protective factors(P<0.05).Sensitivity analysis showed that E=2.015.In both male and female patients,there was no non-linear relationship between stem length and postoperative aseptic loosening(P>0.05).When the model predicted that the probability of aseptic loosening of the prosthesis was 0.80,the Jordan index was the highest(77.77),the accuracy was 92.24%,the sensitivity was 85.63%,the specificity was 92.14%,and the area under the subject working characteristic(ROC)curve was 0.825(95%CI:0.766~0.884,P<0.001).Conclusion The distance of lower limb force line from the center of knee joint,the length of prosthetic stem and the ratio of medullary stalk to femoral diameter are the influencing factors of aseptic loosening after knee prosthesis replacement in patients with distal femoral tumor.It is suggested that surgeons should choose longer prosthetic handle and thicker medullary handle to increase the fit of prosthetic medullary handle to the diameter of femur and medullary cavity diameter.Regular postoperative monitoring of the deviation of the lower limb force line is recommended,with prompt reconstruction of the lower limb force line when necessary.

关键词

假体柄长度/膝关节假体置换术/假体无菌性松动/股骨远端肿瘤

Key words

stem length of prosthesis/knee prosthesis replacement/aseptic loosening of prosthesis/tumor of distal femur