中华全科医学2024,Vol.22Issue(4) :638-641.DOI:10.16766/j.cnki.issn.1674-4152.003469

微血流成像和超声造影对类风湿性关节炎患者病情及滑膜血流评估的一致性分析

Consistency analysis of micro-flow imaging and contrast-enhanced ultrasound in evaluating the condition and synovial blood flow of patients with rheumatoid arthritis

曾鸽 蒋俊杰 孙婞 从惠琴 李巧凤
中华全科医学2024,Vol.22Issue(4) :638-641.DOI:10.16766/j.cnki.issn.1674-4152.003469

微血流成像和超声造影对类风湿性关节炎患者病情及滑膜血流评估的一致性分析

Consistency analysis of micro-flow imaging and contrast-enhanced ultrasound in evaluating the condition and synovial blood flow of patients with rheumatoid arthritis

曾鸽 1蒋俊杰 1孙婞 1从惠琴 1李巧凤1
扫码查看

作者信息

  • 1. 湖州市第三人民医院特检科,浙江湖州 313000
  • 折叠

摘要

目的 采用微血流成像和超声造影检测滑膜血流情况,并分析2种影像学检查方法在评估类风湿性关节炎患者病情中的一致性.方法 选取2019年7月-2022年10月于湖州市第三人民医院接受治疗的50例类风湿关节炎活动期患者作为研究对象.所有患者均采用微血流成像和超声造影检查,记录患者的滑膜血流情况,并在患者接受治疗6个月后再次采用微血流成像和超声造影评价患者的滑膜血流情况,采用Spearman分析研究其结果与实验室指标的相关性.结果 治疗前,微血流成像与超声造影2种检查方式在活动期患者的血流信号检出率(Kappa=0.730,P<0.05)与滑膜血流评价(Kappa=0.797,P<0.05)方面均具有一致性;治疗6个月后,微血流成像与超声造影2种检查方式在缓解期患者的血流信号检出率(Kappa=0.845,P<0.05)与滑膜血流评价(Kappa=0.741,P<0.05)方面均具有一致性;活动期和缓解期的微血流成像和超声造影均与红细胞沉降率、CRP、类风湿因子水平呈正相关(P<0.05),且微血流成像的相关性较超声造影更强.结论 微血流成像和超声造影在类风湿性关节炎患者活动期及缓解期的滑膜血流评估中均具有较强的一致性,且均对病情评估具有临床指导意义.

Abstract

Objective To detect synovial blood flow by micro-flow imaging and contrast-enhanced ultrasound,and ana-lyze the consistency of the two imaging methods in evaluating the condition of patients with rheumatoid arthriti.Methods A total of 50 patients with active rheumatoid arthritis who were treated in Huzhou Third Municipal Hospital from July 2019 to October 2022 were selected as the research objects.All patients were examined by micro-flow imaging and contrast-enhanced ultrasound,and the synovial blood flow of patients was recorded.After 6 months of treatment,the synovial blood flow of patients was evaluated by micro-flow imaging and contrast-enhanced ultrasound again,and.the cor-relation between the results and laboratory indexes was analyzed by Spearman.Results Before treatment,the detection rate of blood flow signals in active patients(Kappa=0.730,P<0.05)and synovial blood flow evaluation(Kappa=0.797,P<0.05)were strongly consistent with each other in the micro-flow imaging and contrast-enhanced ultrasound.After 6 months'treatment,the detection rate of blood flow signals(Kappa=0.845,P<0.05)and synovial blood flow e-valuation(Kappa=0.741,P<0.05)of patients in remission were both consistent in the micro-flow imaging and contrast-enhanced ultrasound.Micro-flow imaging and contrast-enhanced ultrasound were positively correlated with erythrocyte sedimentation rate,CRP and rheumatoid factor levels in both active and remission stages(P<0.05),and the correlation of micro-flow imaging was stronger than that of contrast-enhanced ultrasound.Conclusion Micro-flow imaging and con-trast-enhanced ultrasound have strong consistency in the assessment of synovial blood flow in patients with rheumatoid ar-thritis in active stage and remission stage,and both have clinical guiding significance for disease assessment.

关键词

类风湿性关节炎/微血流成像/超声造影/滑膜血流

Key words

Rheumatoid arthritis/Micro-flow imaging/Contrast-enhanced ultrasound/Synovial blood flow

引用本文复制引用

基金项目

浙江省医药卫生科技计划(2021KY1098)

出版年

2024
中华全科医学
中华预防医学会,安徽省全科医学会

中华全科医学

CSTPCD
影响因子:1.688
ISSN:1674-4152
参考文献量22
段落导航相关论文