在隧道衬砌中安装换热装置可进行地热能源的利用,为隧道上部建筑供热或供冷,但是热激活会对周围土体饱和度产生影响,从而使对水敏感的土体如膨胀土等产生形变,进而可能影响隧道结构受力状态.该研究对能源隧道周围土壤中的热量和水分传导进行了数值模拟分析.通过建立三维有限元模型,研究土壤类型和地下水位对能源隧道水力学行为的影响,并深入了解土体饱和度对换热效率的影响.当饱和地下水位高于隧道时,应考虑自然对流对换热的影响,低于隧道时则不宜用简化的干燥假设来评估换热效率,该研究结果可用于非饱和区域能源隧道的热激活评估.
Numerical Simulation Assessment of the Unsaturated Soils Behavior Nearby the Energy Tunnel
Geothermal energy can be utilized by installing heat exchange devices in tunnel lining for heating of cooling for the upper building of the tunnel.But thermal activation can affect the degree of saturation of surrounding soil to cause deformation of water sensitive soil such as expansive soil,which may affect the stress state of the tunnel struc-ture.This study conducted a numerical analysis of heat and moisture transfer in the soil around energy tunnels.A 3D finite element model was developed to study the influence of soil type and groundwater level on the hydraulic behavior of energy tunnels.The influence of soil saturation on heat transfer efficiency was deeply studied.When the ground-water level is higher than the tunnel,the effect of natural convection on heat transfer should be taken into account.When the level is lower than the tunnel,it is not appropriate to assess heat transfer efficiency by the simplified dry assumption.The results can be used for thermal activation evaluation of energy tunnels in unsaturated regions.

energy tunnelunsaturated soilheat and moisture transfernumerical simulation

马春景、洪海件、喻卫华

展开 >

广州市市政集团有限公司,广东广州 510060

广州建筑股份有限公司,广东广州 510030

广州市建筑集团有限公司,广东广州 510030

能源隧道 非饱和土 水热迁移 数值模拟

广东省住建厅研究开发项目广州市建筑集团有限公司科技项目

2023-K9-240562BH20230317604

2024

市政技术
中国市政工程协会 北京市政路桥股份有限公司 北京市政建设集团有限责任公司 北京市市政工程研究院

市政技术

影响因子:0.385
ISSN:1009-7767
年,卷(期):2024.42(4)
  • 11