城市化进程的加速使得污水泵站在城市水环境治理中的作用日益凸显,但同时也带来了能耗问题,对排水系统减污降碳构成挑战.以广州某泵站为例,探讨变频技术在泵站节能降耗、减污降碳方面的应用效果.通过系统分析变频技术改造前后泵站的运行数据,发现变频技术能有效应对进水流量的周期性波动,稳定控制泵站运行水位,显著提升泵站运行效能.变频技术改造显著降低了泵站能耗,吨水耗电量由0.125 kW·h降至0.113kW·h,全年耗电量同比降低7.3%,全年可节约电能达42万kW·h,全年可减少约267.9 tCO2排放;前池水质呈现显著改善趋势;泵站运行水位稳定控制在正常范围,全年平均水位同比降低15.6%.表明变频技术的应用能有效实现泵站节能降耗,助力排水系统减污降碳.建议在污水泵站中推广应用变频技术,并结合自动控制系统,以实现泵站运行的自动化和智能化,进一步优化能效,助力整个污水处理行业绿色低碳发展.
Application of Frequency Conversion Technology in Energy Saving and Consumption Reduction of Sewage Pumping Station Under the Background of Carbon Emission Reduction
The application of sewage pumping stations in the management of urban water environment has increased by the acceleration of urbanization,while also causing energy consumption and challenging the reduction of pollution and carbon emissions in drainage systems.Taking a pumping station in Guangzhou as an example,this paper ex-plores the application effects of variable frequency technology in energy saving,consumption reduction,and pollu-tion and carbon emission reduction at pumping station.By systematically analyzing the operational data of the pump-ing station before and after the variable frequency technology transformation,it was found that variable frequency technology can effectively solve the cyclical fluctuations in influent flow,stable control the pumping station's oper-ating water level,and significantly improve the operational efficiency of the pumping station.The transformation with variable frequency technology significantly reduced the energy consumption of the pumping station,with the electricity consumption per ton of water dropping from 0.125 kW·h to 0.113 kW·h,a year-on-year reduction of 7.3%in annual electricity consumption,annually electricity saving up to 420 000 kW h,and reducing carbon dioxide emissions by approximately 267.9 tCO2 annually;The water quality in the front pool showed a significant im-provement trend;The operating water level of the pumping station was stably controlled within the normal range,with an average annual water level reduction of 15.6%than the previous year.This indicates that the application of variable frequency technology can effectively achieve energy saving and consumption reduction at pumping station,aiding the reduction of pollution and carbon emissions in drainage systems.It is recommended to promote the appli-cation of frequency conversion technology in sewage pumping station,combined with automated control systems,to achieve the automation and intelligent operation of pumping stations.This will further optimize energy efficiency and support the green and low-carbon development of the entire wastewater treatment industry.

sewage pumping stationfrequency conversion technologyenergy conservation and emission reduc-tionoperational efficiencygreen and low-carbon development

聂云飞、柯臻玮

展开 >

广州市城市排水有限公司,广东 广州 510700

污水泵站 变频技术 节能降耗 运行效率 绿色低碳发展

2024

市政技术
中国市政工程协会 北京市政路桥股份有限公司 北京市政建设集团有限责任公司 北京市市政工程研究院

市政技术

影响因子:0.385
ISSN:1009-7767
年,卷(期):2024.42(12)