Simulation Analysis and Evaluation of Building Noise on Upper Cover of Genshanmen High-Speed Train Operation Station
In order to improve the utilization rate of urban central land,it is a necessary trend to adopt large-scale comprehensive three-dimensional development on the upper cover of the operation station.Noise prediction and evaluation is one of the important tasks that need to be carried out in the early stage of the upper cover development project.In this article,taking the building on the upper cover of the Genshanmen High-speed Train operation station as an example,the noise status is evaluated using the actual measurement method and simulation prediction method.Due to the large development area on the upper cover of the project,in order to better conduct subsequent evaluations,the upper cover development area will be divided into clusters A~D,F~H,and K~J.The environmental noise status of the project area is understood through the actual measurement approach,and the main noise sources are identified.Basic data such as the intensity of main noise sources are obtained through on-site monitoring,and the environmental noise of the proposed building is predicted and evaluated by combining the Canda/A noise prediction software.