首页|复合保温板与加气混凝土砌块墙体一体化施工力学性能研究

复合保温板与加气混凝土砌块墙体一体化施工力学性能研究

扫码查看
针对复合保温板与砌块填充墙连接的安全性,采用HC-MD60 高精度铆钉拉拔仪,进行锚栓抗拉承载力和复合保温板拉伸黏结强度现场原位检测试验.测试结果表明:锚栓抗拉承载力平均值为2.345 kN,复合保温板表面抗裂加强层与保温芯材之间的黏结强度平均值为0.17 MPa,复合保温板内侧黏接层与砌块墙体黏结强度为0.1 MPa,黏锚结合的力学性能满足DB/T 29-281-2020《天津市外模板现浇混凝土复合保温系统应用技术规范》要求.
Study on Mechanical Properties of Composite Insulation Board and Aerated Concrete Block Wall in Integrated Construction
In situ tests of the tensile capacity of anchor bolt and the tensile bond strength of composite insulation board were carried out by HC-MD60 high precision rivet drawing instrument.The test results are:The average ten-sile strength of anchor bolt is 2.345 kN,the average bond strength between the surface crack strengthening layer of composite insulation board and the thermal insulation core material is 0.17 MPa,and the bonding strength between the inner bonding layer of composite insulation board and the block wall is 0.1MPa.The me-chanical properties of the combination of cement and anchor meet the requirements of DB/T29-281-2020"Technical Code for Application of Composite Insulation System of Cast-in-place Concrete with External Formwork in Tianjin".

composite insulation boardmechanical propertiesaerated concreteblock wall

于敬海、吴晓萌、刘维、杨洪盛

展开 >

天津大学建筑设计规划研究总院有限公司,天津 300073

天津大学建筑工程学院,天津 300072

天津市建筑工程质量检测中心有限公司,天津 300193

天津速珀瑞节能建材科技有限公司,天津 301906

展开 >

复合保温板 力学性能 加气混凝土 砌块墙体

2024

天津建设科技
天津市建设科技信息中心 天津市市政工程研究院

天津建设科技

影响因子:0.299
ISSN:1008-3197
年,卷(期):2024.34(3)
  • 3