消防应急通信设备经常在恶劣的环境和条件下使用,因此面临着较高的故障风险.这些故障可能来自于设备、网络及电源等多个方面,需要快速和准确地定位和修复这些故障,以确保通信的连续性.分析消防应急通信系统的关键组件,针对探测器故障、电源故障及通信故障等常见问题,设计相应的故障处理方案.试验结果表明,跨网络协同管理与故障处理系统在各类故障发生时均能迅速响应,平均处理时间分别为 67.5 s、45 s及 60 s,证实系统的可行性,提高消防安全水准.
Design of Cross Network Collaborative Management and Fault Handling System in Fire Emergency Communication
Fire emergency communication equipment is often used in harsh environments and conditions,thus facing a high risk of failure.These faults may come from multiple aspects such as equipment,network and power supply,etc.,and need to be quickly and accurately located and repaired to ensure communication continuity.Analyze the key components of the fire emergency communication system,and design corresponding fault handling solutions for common problems such as detector failures,power failures,and communication failures.The experimental results show that the cross network collaborative management and fault handling system can respond quickly to various faults,with an average processing time of 67.5 s,45 s,and 60 s,respectively,confirming the feasibility of the system and improving the level of fire safety.