首页|输电线路防外破智能监测系统设计与实现研究

输电线路防外破智能监测系统设计与实现研究

Design and Implementation of Intelligent Monitoring System for Preventing External Breakage of Transmission Lines

扫码查看
输电线路的安全性对电网稳定运行至关重要,然而传统的监测方法由于效率低下且能耗较高,已逐渐无法满足现代电力系统的需求.针对线路周围可能出现的异常震动问题,设计并实现了一种输电线路防外破智能监测系统.首先详细分析系统结构,其次对系统的具体设计展开研究,包括监测装置的硬件设计和嵌入式软件设计、上位机软件设计以及服务器设计,最后进行系统的实现与测试.通过该研究,旨在提高电网的安全运行水平,为输电线路防外破提供一种新的解决方案.
The safety of transmission lines is very important to the stable operation of power grid.However,the traditional monitoring methods have gradually failed to meet the needs of modern power systems because of their low efficiency and high energy consumption.Aiming at the possible abnormal vibration around the transmission line,an intelligent monitoring system for preventing external damage of transmission lines is designed and implemented.Firstly,the system structure is analyzed in detail.Secondly,the specific design of the system is studied,including the hardware design and embedded software design of the monitoring device,the software design of the upper computer and the server design.Finally,the system is implemented and tested.Through this research,the purpose is to improve the safe operation level of power grid and provide a new solution for the prevention of external damage of transmission lines.

intelligent monitoring systemtransmission linesprevent external rupture

李盛举、韩璐

展开 >

国网江苏省电力有限公司滨海县供电分公司,江苏 盐城 224000

智能监测系统 输电线路 防外破

2024

通信电源技术
武汉普天通信设备集团有限公司

通信电源技术

影响因子:0.389
ISSN:1009-3664
年,卷(期):2024.41(9)
  • 5