首页|光伏并网变电站继电保护整定优化研究

光伏并网变电站继电保护整定优化研究

扫码查看
针对光伏并网变电站的继电保护整定优化问题,文章分析包含分布式光伏的供电系统结构及其参数,提出考虑光伏并网影响的短路电流计算方法.在此基础上,详细探讨变压器保护和线路保护的电流定值与动作时间整定原则,并给出具体的整定建议.通过合理的保护整定优化,可以有效提高光伏并网变电站的保护性能,提升系统的安全性和可靠性.
Research on Relay Protection Setting Optimization of Photovoltaic Grid-Connected Substation
Aiming at the optimization of relay protection setting in photovoltaic grid-connected substations,this paper analyzes the structure and parameters of power supply system including distributed photovoltaic,and puts forward a calculation method of short-circuit current considering the influence of photovoltaic grid-connected substation.On this basis,the current setting and action time setting principles of transformer protection and line protection are discussed in detail,and specific setting suggestions are given.Through reasonable protection setting optimization,the protection performance of photovoltaic grid-connected substation can be effectively improved,and the safety and reliability of the system can be improved.

photovoltaic grid connectionsubstationrelay protection setting

曹洋

展开 >

国网沙洋县供电公司,湖北荆门 448200

光伏并网 变电站 继电保护整定

2024

通信电源技术
武汉普天通信设备集团有限公司

通信电源技术

影响因子:0.389
ISSN:1009-3664
年,卷(期):2024.41(20)