Intelligent Control Method of Channel Load Rate of Electric Power Emergency Communication Network
Aiming at the problem that the control range of channel load rate in traditional power emergency communication network is limited,this paper proposes an innovative intelligent control method of channel load rate.The wireless gateway protocol is used to calculate the channel load rate and optimize the data acquisition process,and the channel load rate data is pre-allocated.After the output format of the channel load status word is determined by the bit segment of the load status word and the actual channel load situation,the near-end policy optimization(PPO)algorithm is used to screen the control elements,and the Base-Frame Processing Algorithm(BFP)is combined to intelligently control the channel load rate.The experiment shows that after applying this method,when the channel load rate is 72%,the maximum adjustable range of the channel load rate of the power emergency communication network can reach 90%.
communication networkchannel load ratechannel regulationintelligent regulation