首页|基于光纤通信的特高压直流输电线路故障检测方法研究

基于光纤通信的特高压直流输电线路故障检测方法研究

扫码查看
随着特高压直流输电技术的广泛应用,高效可靠的特高压直流输电线路故障检测方法成为保障电网安全稳定运行的关键.提出一种基于光纤通信的特高压直流输电线路故障检测方法,涵盖数据采集、信号处理、数据传输以及故障诊断 4 个环节.实验结果表明,与传统行波法相比,所提方法在故障检测率、定位精度及响应时间等方面均有显著提升,为特高压直流输电线路的安全运行提供了有力保障.
Research on Fault Detection Method of Ultra-High Voltage Direct Current Transmission Line Based on Optical Fiber Communication
With the wide application of ultra-high voltage direct current transmission technology,an efficient and reliable fault detection method for ultra-high voltage direct current transmission lines has become the key to ensure the safe and stable operation of the power grid.This paper proposes a fault detection method for ultra-high voltage direct current transmission lines based on optical fiber communication,which covers four links:data acquisition,signal processing,data transmission and fault diagnosis.The experimental results show that,compared with the traditional traveling wave method,the proposed method has significantly improved the fault detection rate,positioning accuracy and response time,which provides a strong guarantee for the safe operation of ultra-high voltage direct current transmission lines.

ultra-high voltage direct current transmissionoptical fiber communicationfault detection

王高、陈浩

展开 >

国网陕西省电力有限公司超高压公司,陕西 西安 710026

特高压直流输电 光纤通信 故障检测

2024

通信电源技术
武汉普天通信设备集团有限公司

通信电源技术

影响因子:0.389
ISSN:1009-3664
年,卷(期):2024.41(24)