首页|Swab culture monitoring of automated endoscope reprocessors after high-level disinfection

Swab culture monitoring of automated endoscope reprocessors after high-level disinfection

扫码查看
AIM:To conduct a bacterial culture study for monitoring decontamination of automated endoscope reprocessors (AERs) after high-level disinfection (HLD).METHODS:From February 2006 to January 2011,authors conducted randomized consecutive sampling each month for 7 AERs.Authors collected a total of 420 swab cultures,including 300 cultures from 5 gastroscope AERs,and 120 cultures from 2 colonoscope AERs.Swab cultures were obtained from the residual water from the AERs after a full reprocessing cycle.Samples were cultured to test for aerobic bacteria,anaerobic bacteria,and mycobacterium tuberculosis.RESULTS:The positive culture rate of the AERs was 2.0% (6/300) for gastroscope AERs and 0.8% (1/120)for colonoscope AERs.All the positive cultures,including 6 from gastroscope and 1 from colonoscope AERs,showed monofloral colonization.Of the gastroscope AER samples,50% (3/6) were colonized by aerobic bacterial and 50% (3/6) by fungal contaminations.CONCLUSION:A full reprocessing cycle of an AER with HLD is adequate for disinfection of the machine.Swab culture is a useful method for monitoring AER decontamination after each reprocessing cycle.Fungal contamination of AERs after reprocessing should also be kept in mind.

Automated endoscope reprocessorGastrointestinal scopeHigh-level disinfectionSwab cultureMonitoringDecontamination

Lung-Sheng Lu、Keng-Liang Wu、Yi-Chun Chiu、Ming-Tzung Lin、Tsung-Hui Hu、King-Wah Chiu

展开 >

Division of Hepato-Gastroenterology, Department of Internal Medicine, Chang Gung Memorial Hospital-Kaohsiung Medical Center, Chang Gung University College of Medicine, Kaohsiung 83305, Taiwan, China

2012

世界胃肠病学杂志(英文版)
太原消化病研治中心

世界胃肠病学杂志(英文版)

SCI
影响因子:1.001
ISSN:1007-9327
年,卷(期):2012.18(14)
  • 1
  • 14