扫码查看
高精度辐射定标对于无人机遥感数据定量化应用至关重要.以大疆精灵 4 RTK多光谱传感器为例,基于多种典型地物和人工靶标,实现了该传感器全动态范围的辐射定标.在开展真实性检验后,探讨了曝光时间和光谱响应函数对定标结果的影响.研究表明,定标结果具有较高的定标精度,各波段RMSE均优于 3.25%,且脉冲型光谱响应函数更适用于该传感器.另外,曝光时间会对中高亮度地物产生较大影响,容易出现过饱和现象.
Radiometric Calibration of Low-altitude UAV Multispectral Sensor
Radiometric calibration is essential for quantitative remote-sensing applications using UAV multi-spectral sensor.Taking the multispectral sensor onboard DJ P4 RTK UAV as investigated target,integrating vari-ous typical ground objects and artificial targets,this study implements radiometric calibration in full dynamic range of this sensor.After validating the calibration results,this study discusses the influences of exposure time and relative spectral responses on the calibration results.The results show the RMSEs in all bands are less than 3.25%.The pulse relative spectral response is more suitable for this sensor.Meanwhile,the different exposure time can cause the supersaturation for the middle-high brightness surface.

UAVmultispectral sensorradiometric calibrationvalidation