Application of Multidimensional Constrained Weighing to Improve Measurement Accuracy of Belt Scale
By analysing the characteristics of multi-dimensional constrained load cell,the overall structure and the influencing factors of weighing accuracy,calibration method,etc.,it is proposed to use the full-bridge connection to connect the resistive strain gauges in order to obtain better output characteristics.Practical application shows that the cumulative error value of dynamic measurement is lower than 0.5%,which solves the problem of low measurement accuracy of belt scale.