首页|可燃液体储罐区固定式灭火系统管网布置方式的探讨

可燃液体储罐区固定式灭火系统管网布置方式的探讨

扫码查看
为充分发挥固定式灭火系统的作用,有效缩短灭火时间,提高可燃液体储罐火灾的灭火效率,降低火灾对消防人员生命安全的威胁,本文系统调研了国内已建成的固定顶储罐、外浮顶储罐的固定式泡沫灭火系统管网的布置方式和消防冷却水系统的管网布置方式,分析了不同布置方式的优缺点,提出了可燃液体储罐区固定式灭火系统设计及改进的建议.
Discussion on pipe network layout of fixed fire extinguishing system in combustible liquid storage tank area
In order to give full play to the role of the fixed fire ex-tinguishing system,effectively shorten the fire extinguishing time,improve the fire extinguishing efficiency of flammable liquid tank fires,and reduce the threat of fire to the life safety of fire-fighters,this paper systematically investigated the layout of the fixed foam fire extinguishing system pipe network of domestic built fixed roof tanks and external floating roof tanks and the lay-out of the pipe network of the fire cooling water system,and ana-lyzed the advantages and disadvantages of different layout meth-ods,suggestions for the design and improvement of fixed fire ex-tinguishing systems in combustible liquid storage tank areas have been proposed.

combustible liquid storage tankpipeline arrange-mentfixed foam fire extinguishing systemfire cooling water sys-tem

张网、王玥

展开 >

应急管理部天津消防研究所,天津 300381

工业与公共建筑火灾防控技术应急管理部重点实验室,天津 300381

天津市消防安全技术重点实验室,天津 300381

可燃液体储罐区 管网布置 固定式泡沫灭火系统 消防冷却水系统

天津市科技计划项目

22JQNJC01730

2024

消防科学与技术
中国消防协会

消防科学与技术

CSTPCD北大核心
影响因子:0.846
ISSN:1009-0029
年,卷(期):2024.43(3)
  • 11