首页|户外运行光伏组件之接线盒失效分析

户外运行光伏组件之接线盒失效分析

扫码查看
针对光伏组件用光伏接线盒在大型光伏电站现场使用过程中出现的失效现象进行分析研究.通过对光伏接线盒的外观检测、电流-电压(I-V)特性分析以及进一步的解剖测试分析,在二极管解剖出的芯片表面保护环位置发现多处烧熔点,确定是雷击造成的二极管击穿导致接线盒失效.
Failure Analysis of the Junction Box Used for Photovoltaic Module Serviced Outdoor
The failure phenomenon of the junction box used for photovoltaic modules in a large-scale photovoltaic power station was investigated.This investigation involved the visual inspection of the junction box,analysis of its voltage-current(I-V)characteristics,and further dissection testing and analysis.Ultimately,the burn marks were discovered on the protection ring position of the diode's surface after dissection.The failure of the junction box was attributed to diode breakdown induced by lightnin strike.

photovoltaic modulejunction boxfailure analysisdiode

韩会丽、彭祁军、朱灯林

展开 >

河海大学 力学与材料学院,江苏 南京 210000

浙江鑫辉光伏科技有限公司,浙江 乐清 325600

信阳师范大学 建筑节能材料河南省协同创新中心,河南 信阳 464000

光伏组件,接线盒 失效分析 二极管

国家自然科学基金河南省自然科学基金

12105239242300420357

2024

信阳师范学院学报(自然科学版)
信阳师范学院

信阳师范学院学报(自然科学版)

CSTPCD
影响因子:0.446
ISSN:1003-0972
年,卷(期):2024.37(2)
  • 10