首页|基于稳定场地的太阳反射波段基准传递定标及其不确定性评估

基于稳定场地的太阳反射波段基准传递定标及其不确定性评估

扫码查看
空间辐射测量基准作为未来卫星定标的重要标准,为卫星数据的定量化应用提供了重要保障。通过传递定标方法实现辐射基准的传递可以提高卫星遥感器观测数据的整体精度。基于稳定场地的交叉定标作为太阳反射波段传递定标的一种主要方法,因其选定了目标均匀且反射特性较稳定的场地作为辐射基准传递对象,具有可靠性高、稳定性好、传递链条可追溯等优点。以利比亚场地为传递目标,提出一套适合于太阳反射波段的传递定标方法及其不确定性分析方案,系统分析传递定标方法的不确定性,并通过不确定性的敏感性分析给出最优的场地交叉定标的匹配方案。以气象卫星中分辨率光谱成像仪为例,以FY-3D MERSI-Ⅱ和AQUA MODIS为代理数据,针对引入不确定性的主要来源:几何、时间、空间、光谱,利用大气辐射传输模型与双向反射分布函数构建不确定性分析模型,并通过蒙特卡罗方法多次模拟分析出各匹配条件对不确定性影响的敏感性,以利比亚场地为例,以各项不确定性小于1%作为约束,确定场地交叉定标匹配阈值:两遥感器观测天顶角之差应小于±7°,太阳天顶角之差小于±6°,相对方位角之差小于±15°,气溶胶厚度小于0。39,观测场地均匀性小于0。02,此条件下各通道总传递定标不确定性控制在1。5%,定标频次平均一月一次。
Cross calibration over sites and uncertainty assessment for reflective solar bands
The stability of Pseudo-Invariant Calibration Sites(PICS)contributes significantly to the improvement in calibration accuracy.The number of PICS is increasing as the work continues to advance.Therefore,the frequency of cross calibrations based on dessert sites has been significantly increased.Establishing a generic site-based cross calibration and uncertainty analysis method is necessary to confirm calibration uncertainties for different sites.Our study aims to improve the overall accuracy of satellite remote sensor observations by developing a cross calibration method over desert sites.In this study,a cross calibration and uncertainty assessment scheme aiming at solar bands is described,and the optimal matching scheme of the cross calibration is given by sensitivity analysis of the uncertainty.With image data of Libya sites from MODIS and MERSI-Ⅱ,the main uncertainty contributors are found in the geometric,temporal,spatial,and spectral domains.For the four aspects,the uncertainty analysis model is independently constructed using the atmospheric radiative transfer model and the bi-directional reflectance distribution function.The sensitivity of each matching condition to the effect of uncertainty is multiplied and simulated by Monte Carlo method.The geometric and atmospheric distribution patterns of satellite matching data are summarized,which is conducted through statistically analyzing the matching data of MODIS and MERSI-Ⅱ over Libya sites in 2020.The probability distribution density of the matching condition is used as the input condition,and the discrete distribution of the relative deviation of Top-Of-Atmosphere(TOA)reflectance is obtained by the uncertainty analysis model.The standard deviation of the distribution of relative deviations of TOA reflectance is statistically considered the standard uncertainty.After independent analysis of each factor of uncertainty,the total uncertainty is obtained by the Root-Sum-Squared method.The total uncertainty of each channel could be controlled under 1.5%(at)when the difference in sensor zenith angles between the two remote sensors is than±7°,the difference between the solar zenith angles is less than±6°,the aerosol thickness is less than 0.39,and the uniformity of the observation site is less than 0.02.The results between the MODIS reflectance and the digital number recorded by MERSI reveal a good linear relationship.This cross calibration result also has an accuracy in the range of 0.5%-1.5%for each band compared with operational calibrations.Although we only applied the algorithm to MERSI-Ⅱ as a demonstration,our algorithm is applicable to other sensors with few modifications.

remote sensinguncertaintycross calibrationMonte Carlo methodreflection bandmedium resolution imaging spectroradiometer

胡奇、何玉青、徐娜、何兴伟、王玲、王倩、胡秀清、胡滨、徐寒列

展开 >

北京理工大学光电学院光电成像技术与系统教育部重点实验室,北京 100081

许健民气象卫星创新中心,北京 100081

中国气象局中国遥感卫星辐射测量和定标重点开放实验室/国家卫星气象中心(国家空间天气监测预警中心),北京 100081

遥感 不确定性 场地交叉定标 蒙特卡罗方法 反射波段 中分辨率光谱成像仪

国家重点研发计划国家重点研发计划

2018YFB05048002018YFB0504805

2024

遥感学报
中国地理学会环境遥感分会 中国科学院遥感应用研究所

遥感学报

CSTPCD北大核心
影响因子:2.921
ISSN:1007-4619
年,卷(期):2024.28(8)