药物分析杂志2024,Vol.44Issue(2) :307-315.DOI:10.16155/j.0254-1793.2024.02.14

HPLC法测定药用胶塞中常用抗氧剂及可提取硫向丙泊酚中/长链脂肪乳注射液中的迁移

Determination of migration of common antioxidants and extractable sulfur in medical rubber stoppers to propofol medium/long chain fat emulsion injection by HPLC

成婕 江燕 邱怡婷 任锟 赵津池 田甜 张罗红
药物分析杂志2024,Vol.44Issue(2) :307-315.DOI:10.16155/j.0254-1793.2024.02.14

HPLC法测定药用胶塞中常用抗氧剂及可提取硫向丙泊酚中/长链脂肪乳注射液中的迁移

Determination of migration of common antioxidants and extractable sulfur in medical rubber stoppers to propofol medium/long chain fat emulsion injection by HPLC

成婕 1江燕 1邱怡婷 1任锟 1赵津池 2田甜 1张罗红1
扫码查看

作者信息

  • 1. 四川省药品检验研究院,成都 610097
  • 2. 成都康华生物制品股份有限公司,成都 610199
  • 折叠

摘要

目的:建立一种高效液相色谱方法(HPLC),用于考察药用胶塞中常用抗氧剂及可提取硫的提取情况,以及药用胶塞中抗氧剂及可提取硫向丙泊酚中/长链脂肪乳注射液的迁移情况.方法:采用Waters Symmetry RP18(250 mm ×4.6 mm,5 μm)色谱柱,流动相为甲醇-乙腈-1%醋酸水溶液,梯度洗脱,检测波长为277 nm,流速为1 mL·min-1,柱温为35℃.结果:各组分分离度良好;在0.1~20 μg·mL-1范围内线性关系良好,r≥0.999 6;该方法的精密度、稳定性、重复性均良好,RSD均<5.0%;回收率为93.3%~108.7%,RSD为1.8%~12.5%.检出3批药液中均有抗氧剂BHT的迁移,且含量高于其相应人每日允许最大暴露量(PDE)值,有较大安全性风险.结论:该方法具有较高的灵敏度,操作简便,能够用于检测丙泊酚中/长链脂肪乳注射液中抗氧剂的迁移.

Abstract

Objective:To establish a high-performance liquid chromatography(HPLC)method for investigating the extraction of common antioxidants and extractable sulfur in medical rubber stoppers and the migration of antiox-idants and extractable sulfur to propofol medium/long chain fat emulsion injection.Methods:Waters Symmetry RP18(250 mm ×4.6 mm,5 μm)was used as chromatographic column with methanol-acetonitrile-1%acetic acid solution as the mobile phase.Detection wavelength,velocity of flow and column temperature were set to 277 nm,1 mL·min-1 and 35 ℃.Results:Good resolution and linear relationship(r≥0.999 6)in the range of 0.1-20 μg·mL-1 were achieved.This method possesses superior precision,stability,repeatability,and all RSD were less than 5%.The rate of recovery was 93.3%-108.7%,and the RSD was 1.8%-12.5%.The migration of antioxidant BHT was detected in three batches of solution and the content was higher than its corre-sponding permitted daily exposure(PDE)value,which means there is a large safetyrisk.Conclusion:The meth-od represents high sensitivity and is easy to operate,which can effectively detect the migration of antioxidants in propofol medium/long chain fat emulsion injection.

关键词

高效液相色谱法/丙泊酚中/长链脂肪乳注射液/抗氧剂/可提取硫

Key words

high-performance liquid chromatography(HPLC)/propofol medium and long chain fat emulsion in-jection/antioxidants/extractable sulfur

引用本文复制引用

出版年

2024
药物分析杂志
中国药学会

药物分析杂志

CSTPCDCSCD北大核心
影响因子:1.039
ISSN:0254-1793
被引量1
参考文献量17
段落导航相关论文