药物分析杂志2024,Vol.44Issue(3) :373-379.DOI:10.16155/j.0254-1793.2024.03.01

定量核磁共振波谱法测定坎地沙坦酯氨氯地平片中2个活性成分的绝对含量

Determination of absolute contents of candesartan cilexetil and amlodipine besylate in candesartan cilexetil and amlodipine tablets by quantitative nuclear magnetic resonance

张中玲 吴洪海 陈忠奎 翁勤洁
药物分析杂志2024,Vol.44Issue(3) :373-379.DOI:10.16155/j.0254-1793.2024.03.01

定量核磁共振波谱法测定坎地沙坦酯氨氯地平片中2个活性成分的绝对含量

Determination of absolute contents of candesartan cilexetil and amlodipine besylate in candesartan cilexetil and amlodipine tablets by quantitative nuclear magnetic resonance

张中玲 1吴洪海 2陈忠奎 3翁勤洁4
扫码查看

作者信息

  • 1. 浙江大学工程师学院,杭州 310000;杭州先导医药科技有限责任公司,杭州 311100
  • 2. 浙江大学药学院,杭州 310058
  • 3. 杭州先导医药科技有限责任公司,杭州 311100
  • 4. 浙江大学药物安全评价研究中心,杭州 310058;浙江大学台州研究院,台州 318001
  • 折叠

摘要

目的:建立坎地沙坦酯氨氯地平片中坎地沙坦酯及苯磺酸氨氯地平2个活性成分绝对含量的定量核磁共振氢谱测定方法.方法:以坎地沙坦酯化学位移δ5.51,苯磺酸氨氯地平化学位移δ5.31为定量峰,马来酸化学位移δ 6.27为内标定量峰,氘代二甲基亚砜(DMSO-d6)为溶剂,使用超导核磁共振波谱仪采集供试液的氢谱,对坎地沙坦酯氨氯地平片中坎地沙坦酯及苯磺酸氨氯地平2个活性成分绝对含量进行定量测定.结果:该方法专属性强,溶剂峰、水峰及辅料峰对待测定量峰无干扰.坎地沙坦酯在1.580 0~9.480 2 mg·mL-1质量浓度范围内呈现良好的线性关系r=1.000,精密度、重复性及稳定性的RSD分别为0.070%、1.7%和0.68%,低、中、高浓度加标回收率在98.1%~99.2%;苯磺酸氨氯地平在0.983 9~5.903 6 mg·mL-1质量浓度范围内呈现良好的线性关系(r=0.999 9),精密度、重复性及稳定性的RSD分别为0.050%、1.8%和0.79%,低、中、高浓度加标回收率在99.1%~102.0%.运用该方法对2批参比制剂及不同来源的1批样品进行测试,坎地沙坦酯含量在98.10%~98.75%,苯磺酸氨氯地平含量在98.98%~99.60%.结论:该方法检测坎地沙坦酯氨氯地平片中2个活性成分的绝对含量快速、准确,且无需提供2个物质单组分对照品,为坎地沙坦酯氨氯地平片含量测定提供新的方法.

Abstract

Objective:To establish a method for determining the absolute contents of candesartan cilexetil and am-lodipine besylate in candesartan cilexetil and amlodipine tablets by qNMR Methods:The chemical shift δ 5.51 of candesartan cilexetil and δ 5.31 of amlodipine besylate were used as the quantitative peaks.δ 6.27 of maleic acid was the quantitative peak of internal standard.DMSO-d6 was used as the solvent.Results:The method was highly specific and the solvent peak,water peak and excipient peaks did not interfere with the quantitative peaks.Candesartan cilexetil showed a good linear relationship in the concentration range of 1.580 0-9.480 2 mg· mL-1,r=1.000,RSDs of precision,repeatability and stability were 0.070%,1.7%and 0.68%,respectively.The recoveries of low,medium and high concentration spiked were 98.1%-99.2%.The linear range of amlodip-ine besylate was 0.983 9-5.903 6 mg·mL-1(r=0.999 9).The RSDs of precision,repeatability and stability were 0.050%,1.8%and 0.79%,respectively.The recovery of amlodipine besylate was 99.1%-102.0%.This method was used to test two batches of reference preparations and one batch of sample from different sources.The results showed that the content of candesatan cilexetil was between 98.10%to 98.75%,and that of amlldip-ine besylate was between 98.98%to 99.60%.Conclusion:This method is rapid and accurate and it is not nec-essary to use a single component reference substance.This method provides a new method to determine the content to candesartan cilexetil and amlodipine tablets.

关键词

坎地沙坦酯/苯磺酸氨氯地平/绝对含量/定量核磁共振法

Key words

candesartan cilexetil/amlodipine besilate/absolute content/quantitative nuclear magnetic resonance