医学新知2024,Vol.34Issue(5) :530-537.DOI:10.12173/j.issn.1004-5511.202404017

超声和磁共振成像测量前列腺大小与体积的一致性研究

Consistency of ultrasonography and magnetic resonance imaging in measuring prostate size and volume

毛晓丽 訾豪 张洁 刘双苔 黄桥 李柄辉 曾宪涛
医学新知2024,Vol.34Issue(5) :530-537.DOI:10.12173/j.issn.1004-5511.202404017

超声和磁共振成像测量前列腺大小与体积的一致性研究

Consistency of ultrasonography and magnetic resonance imaging in measuring prostate size and volume

毛晓丽 1訾豪 2张洁 3刘双苔 4黄桥 5李柄辉 5曾宪涛5
扫码查看

作者信息

  • 1. 武汉工程大学校医院超声科(武汉 430074)
  • 2. 武汉大学中南医院泌尿外科(武汉 430071);武汉大学中南医院循证与转化医学中心(武汉 430071)
  • 3. 武汉大学中南医院离退休工作处(武汉 430071)
  • 4. 武汉大学中南医院泌尿外科(武汉 430071)
  • 5. 武汉大学中南医院循证与转化医学中心(武汉 430071)
  • 折叠

摘要

目的 评价超声和磁共振成像(magnetic resonance imaging,MRI)测量前列腺大小与体积的一致性.方法 本研究数据来源于中国人群膀胱癌和良性前列腺增生研究数据,使用超声和MRI测量前列腺增生患者的前列腺大小与体积.前列腺的大小采用左右径、前后径和上下径表示,并根据公式计算前列腺体积.采用配对样本Wilcoxon符号秩检验进行,使用Bland-Altman分析法评估两种测量结果的一致性.结果 本研究共纳入103名患者.超声测得的前列腺平均左右径、前后径、上下径分别为(5.789±0.835)cm、(5.054±0.915)cm、(4.530±0.882)cm,中位体积为 66.690(49.179,96.110)mL.MRI测得的前列腺中位左右径、前后径、上下径分别为5.800(5.300,6.400)cm、5.000(4.650,5.600)cm、4.300(3.900,4.800)cm,中位体积为 65.520(49.678,90.714)mL.超声与MRI测量前列腺大小结果一致性良好,二者间无统计学差异.一致性分析显示超声与MRI测量前列腺体积结果间的偏差较小,平均为1.329 mL.结论 超声与MRI测量前列腺大小与体积的一致性良好,在临床实践中,应根据具体情况选择合适的前列腺大小与体积测量方法.

Abstract

Objective To evaluate the consistency of ultrasonography and magnetic resonance imaging(MRI)in measuring of prostate size and volume.Methods The data of this study was from the research data of the bladder cancer and benign prostatic hyperplasia study in Chinese population.The study examined the prostates of participants using both ultrasonography and MRI.Prostate size was measured by the transverse diameter,antero-posterior diameter,and supero-inferior diameter,and volume was calculated using a formula.Groups comparisons were conducted using Wilcoxon signed rank test and the consistency of measurement results was evaluated using Bland-Altman analysis.Results 103 patients with benign prostatic hyperplasia were included.The mean transverse diameter,mean antero-posterior diameter,and mean supero-inferior diameter of the prostate measured by ultrasonography was(5.789±0.835)cm,(5.054±0.915)cm,and(4.530±0.882)cm respectively,and the median volume was 66.690(49.179,96.110)mL.The median transverse diameter,median antero-posterior diameter and median supero-inferior diameter of the prostate measured by MRI was 5.800(5.300,6.400)cm,5.000(4.650,5.600)cm,and 4.300(3.900,4.800)cm respectively,and the median volume was 65.520(49.678,90.714)mL.The prostate size results had good agreement between ultrasound and MRI measurements,with no statistical difference between the two measurements.The prostate volume measured by ultrasonography had a small deviation compared to the MRI measurement,with an average difference of 1.329 mL.Conclusion The consistency between ultrasonography and MRI in measuring prostate size and volume is strong.In clinical practice,the appropriate method for measuring prostate size and volume should be chosen based on the specific circumstances.

关键词

良性前列腺增生/前列腺/大小/体积/超声/磁共振成像/一致性

Key words

Benign prostatic hyperplasia/Prostate/Size/Volume/Ultrasonography/Magnetic resonance imaging/Consistency

引用本文复制引用

基金项目

国家重点研发计划"数字诊疗装备研发"重点专项(2016YFC0106300)

湖北省技术创新专项重大项目(2016ACA152)

出版年

2024
医学新知
武汉大学中南医院,中国农工民主党湖北省委医药卫生工作委员会

医学新知

CSTPCD
影响因子:0.243
ISSN:1004-5511
参考文献量30
段落导航相关论文