医学新知2024,Vol.34Issue(6) :665-673.DOI:10.12173/j.issn.1004-5511.202402070

《结直肠手术患者尿管拔除评估量表》的编制与信效度检验

Reliability and validity test of Urinary Catheter Removal Assessment Scale for Patients with Colorectal Surgery

殷燕 张春华 何文斌 段静 李思思 解萧宇 骆曼 孙文 武玲
医学新知2024,Vol.34Issue(6) :665-673.DOI:10.12173/j.issn.1004-5511.202402070

《结直肠手术患者尿管拔除评估量表》的编制与信效度检验

Reliability and validity test of Urinary Catheter Removal Assessment Scale for Patients with Colorectal Surgery

殷燕 1张春华 2何文斌 3段静 3李思思 3解萧宇 3骆曼 3孙文 3武玲3
扫码查看

作者信息

  • 1. 武汉大学中南医院创面/造口诊疗中心(武汉 430071)
  • 2. 武汉大学中南医院护理部(武汉 430071)
  • 3. 武汉大学中南医院结直肠肛门外科(武汉 430071)
  • 折叠

摘要

目的 在加速康复外科理念的指导下编制《结直肠手术患者尿管拔除评估量表》,并检验其信效度.方法 通过文献查阅法、专家访谈法,结合临床实践分析影响结直肠手术患者尿管拔除时机的相关因素,通过 2 轮德尔菲专家函询,形成初始版量表.采用方便抽样法选取 2023 年 4 月至 10 月在湖北省某三级甲等医院的 137例结直肠手术患者进行问卷调查,并进行信效度检验,分析量表的敏感性和特异性,确定最佳阈值.结果 该量表包括 3 个维度,20 个条目.累计方差贡献率为 83.582%.条目水平的内容效度指数为0.96~1.00,量表水平的内容效度指数为0.91.量表各条目与所属维度的相关系数为 0.637~0.852,维度间的相关系数为 0.602~0.774,各维度与总量表的相关系数为 0.889~0.918.量表各维度的Cronbach's α系数为 0.914~0.957,量表总的Cronbach's α系数为 0.931;各维度的分半信度为 0.913~0.942,量表总的分半信度为 0.958.量表ROC曲线下面积为 0.934[95%CI(0.892,0.975)].当量表评分为 29.5 分时,该量表的敏感度、特异度和约登指数最高,分别为 0.870、0.912 和 0.782.评分≤29.5 分时,可考虑拔除尿管.结论 本研究构建的《结直肠手术患者尿管拔除评估量表》具有较好的信效度,经过临床验证可较准确的判断结直肠手术患者尿管拔除时机.

Abstract

Objective To construct the Urinary Catheter Removal Assessment Scale for Patients with Colorectal Surgery under the guidance of the concept of enhanced recovery after surgery(ERAS),and to test reliability and validity.Methods Under the guidance of the concept of ERAS,the relevant factors affecting the timing of urinary catheter removal in patients with colorectal surgery were analyzed through literature review and expert interview,and combined with clinical practice.The initial scale was formed through 2 rounds of Delphi consultations.A total of 137 patients undergoing colorectal surgery in a grade-Ⅲ hospital in Hubei province from April to October 2023 were selected by convenience sampling method for questionnaire survey,and the reliability and validity test was conducted to analyze the sensitivity and specificity of the scale and determine the optimal threshold.Results The scale consists of 3 dimensions and 20 items.The cumulative variance contribution rate was 83.582%.The content validity index was 0.96~1.00 at the item level and 0.91 at the scale level.The correlation coefficient between each item and its dimension ranged from 0.637 to 0.852,between the dimensions ranged from 0.602 to 0.774,and between each dimension and the total table ranged from 0.889 to 0.918.The Cronbach's α coefficient of each dimension was 0.914~0.957,and of the total scale was 0.931.The partial half-reliability of each dimension was 0.913~0.942,and of the scale was 0.958.The area under the ROC curve of the scale was 0.934[95CI%(0.892,0.975)].When the scale score was 29.5,the sensitivity,specificity and Yoden index of the scale were the highest,which were 0.870,0.912 and 0.782,respectively.When the score is less than 29.5,the urinary catheter could be removed.Conclusion The catheter removal tool constructed in this study has good reliability and validity,and could accurately judge the timing of catheter removal in patients with colorectal surgery through clinical verification.

关键词

结直肠/加速康复外科/尿管拔除/量表/信度/效度

Key words

Colorectal/Enhanced recovery after surgery/Urinary catheter removal/Scale/Reliability/Validity

引用本文复制引用

基金项目

国家自然科学基金青年科学基金项目(82202915)

武汉大学中南医院护理学科培育项目(HLXKPY202101)

武汉大学护理学专项科研培育基金重点类项目(LCHL202304)

出版年

2024
医学新知
武汉大学中南医院,中国农工民主党湖北省委医药卫生工作委员会

医学新知

CSTPCD
影响因子:0.243
ISSN:1004-5511
段落导航相关论文