Quality Evaluation of Cisatracurium Besilate Injection
Objective To evaluate the quality of cisatracurium besilate injection produced by domestic manufacturers.Methods A comprehensive evaluation of 104 batches of samples was carried out using statutory testing methods combined withexploratory research,including related substances,1,5-pentanediol diacrylate,residual solvents,genotoxic impurities of benzenesulfonate esters,infrared spectrum,and endotoxin examination.The quality of domestic products and the controllability of current specifications were comprehensively evaluated.Results According to the statutory tests,the qualified rate of 104 batches of samples was 100.0%.The exploratory research showed that the results of related substances in the samples produced by 6 manufacturers were far below the limit,and no genotoxic impurities of benzenesulfonate esters were detected.However,the results showed that there was variability in 1,5-pentanediol diacrylate,as well as residual solvents.Conclusions The quality of the cisatracurium besilate injection is good,and the current specifications should be further improved and unified.It was proposed that the infrared spectrum,related substance,and 1,5-pentanediol diacrylate method be added or revised,and the limit of endotoxin strictly controlled.It was proposed that manufacturers pay attention to the quality of API and control injection production.