首页|高频超声联合剪切波弹性成像评估产后腹直肌分离不同时间仿生物电刺激治疗的疗效

高频超声联合剪切波弹性成像评估产后腹直肌分离不同时间仿生物电刺激治疗的疗效

扫码查看
目的:利用高频超声联合剪切波弹性成像技术(SWE)评估产后腹直肌分离(DRA)患者不同时间仿生物电刺激治疗的疗效.方法:将 2021 年 10 月~2022 年 11 月于我院就诊的DRA患者根据治疗时间与方法的不同分为早期治疗组、晚期治疗组及期待治疗组(对照组),分析比较三组治疗前后腹直肌间距(IRD)、厚度、平均杨氏模量值(Emean)之间的差异;对治疗后三组IRD与腹直肌厚度、Emean,Emean与临床腹壁肌肉功能进行相关性分析.结果:早期治疗组、晚期治疗组及对照组治疗总有效率分别为 72.0%(36/50)、50.0%(20/40)、24.0%(12/50).治疗后早期治疗组、晚期治疗组与对照组相比,IRD、腹直肌厚度、Emean差异均具有统计学意义(P<0.05);早期治疗组与晚期治疗组相比,Emean差异具有统计学意义(P<0.05).IRD与腹直肌厚度及Emean呈中度负相关;Emean与腹直肌肌力及肌耐力时间呈高度正相关.结论:高频超声联合SWE可综合、有效评估产后DRA患者治疗疗效;仿生物电刺激治疗DRA患者疗效显著,且早期行仿生物电刺激治疗效果更佳.
High-frequency Ultrasonography Combined with Shear Wave Elastography to Evaluate the Efficacy of Biomimetic Electrical Stimulation at Different Times for Postpartum Diastasis Rectus Abdominis
Objective To evaluate the efficacy of biomimetic electrical stimulation at different times in patients with postpar-tum diastasis rectus abdominis(DRA)using high-frequency ultrasonography combined with shear wave elastography(SWE).Methods DRA patients who visited the People's Hospital Affiliated with Hubei University of Medicine from Octo-ber 2021 to November 2022 were divided into early treatment group,late treatment group,and expectant treatment group(control group)based on different treatment time periods and methods.The differences in inter-rectus distance(IRD),thickness,and average Young's modulus value(Emean)bewteen the three groups before and after treatment were analyzed and compared.Correlation analysis was also performed between IRD and rectus abdominis thickness and Emean,as well as between Emean and abdominal wall muscular function.Results The total effective rates of the early treatment group,late treatment group,and control group were 72.0%(36/50),50.0%(20/40),and 24.0%(12/50),respectively.After treatment,the early treatment group and late treatment group had significant differences in IRD,rectus abdominis thick-ness,and Emean compared with the control group(P<0.05).The difference in Emean was also significant between the ear-ly treatment group and the late treatment group(P<0.05).IRD was moderately negatively correlated with rectus abdominis thickness and Emean,whereas Emean was highly positively correlated with rectus abdominis muscle strength and muscle endurance time.Conclusion High-frequency ultrasonography combined with SWE can comprehensively and effectively e-valuate the therapeutic efficacy of patients with postpartum DRA.Biomimetic electrical stimulation has a remarkable effect on DRA patients,especially at early application.

UltrasonographyShear wave elastographyBiomimetic electrical stimulationDiastasis rectus abdominis

李威、肖飞、李甜甜、郑霜、郑光美、胡培、肖彬、景红霞

展开 >

湖北医药学院附属人民医院超声影像中心,湖北 十堰 442000

超声检查 剪切波弹性成像 仿生物电刺激治疗 腹直肌分离

湖北省卫生健康科研基金湖北省十堰市引导性科研项目

WJ2021F04122Y53

2024

湖北医药学院学报
湖北医药学院

湖北医药学院学报

影响因子:0.504
ISSN:1006-9674
年,卷(期):2024.43(4)