针对目前配电网拓扑识别时多源融合数据利用率低的问题,提出了一种基于多源数据融合的配电网拓扑识别方法.首先,设计了一种多源数据时间尺度对齐方法.其次,提出了一种基于线性外推的伪测量数据生成方法,从而提高拓扑识别方法的数据精度.最后,建立了多源数据融合配电网离散化和线性化最优拓扑识别方法.在试验阶段,以IEEE 33 馈线系统为例验证所提方法.试验结果表明,当节点注入功率数据的实时测量误差为 30%、伪测量误差为 5%时,所提方法拓扑识别准确率为 70.98%,较无融合方法提升了5.86%.所提方法对提高配电网拓扑识别准确率具有一定指导作用.
Research on Topology Identification Method of Distribution Network Based on Multi-Source Data Fusion
Aiming at the current problem of low utilization of multi-source fusion data in distribution network topology identification,a method of distribution network topology identification based on multi-source data fusion is proposed.Firstly,a multi-source data time scale alignment method is designed.Secondly,a pseudo-measurement data generation method based on linear extrapolation is proposed to improve the data accuracy of the topology identification method.Finally,a discretized and linearized optimal topology identification method for multi-source data fusion distribution networks is established.In the experimental stage,the IEEE 33 feeder system is used as an example to validate the proposed method.The text results show that the topology identification accuracy of the proposed method is 70.98%when the real-time measurement error of the node injected power data is 30%and the pseudo-measurement error is 5%,which is an improvement of 5.86%over the no-fusion method.The proposed method has a certain guiding role in improving the accuracy of topology identification in distribution network.

Distribution networkTopology identificationData fusionDiscretizationLinearization

刘祥波、王森、延凯、扈佃爱、高芳、梁伟

展开 >

国网日照供电公司,山东 日照 276826

配电网 拓扑识别 数据融合 离散化 线性化

2024

自动化仪表
中国仪器仪表学会 上海工业自动化仪表研究院

自动化仪表

CSTPCD
影响因子:0.655
ISSN:1000-0380
年,卷(期):2024.45(3)
  • 8