Research on Data Monitoring Method of Fiber Optic Self-Healing System Combined with Optical-Magnetic-Electrical Pulses
To solve the problem of poor anti-maloperation of manipulator in fiber optic self-healing system,a data monitoring method of fiber optic self-healing system combining with optical-magnetic-electrical pulses is proposed.Firstly,the data of the manipulator of the fiber optic self-healing system are obtained by photoelectric and magnetoelectric encoders respectively,and wavelet filtering and other methods are used to eliminate the influence of noise on the monitoring data.Secondly,the fiber optic self-healing system manipulator data acquisition is carried out by using the complementary checking methods of photoelectric encoders and magnetoelectric encoders,so that multiple encoders cooperate with each other and check each other,thus improving the accuracy of the manipulator monitoring data and avoiding the data bias caused by the failure of a single device.Finally,it is assessed in a test environment.The test results show that the monitoring accuracy of the fiber optic self-healing system is 99.87%.This method can effectively improve the accuracy of manipulator monitoring data of fiber optic self-healing system.