Research on Response Time of Temperature Sensor under Steam Medium
According to the response time requirements of temperature sensor for reactor research,develop and design,and regarding the issue of temperature sensor unable to provide specific values of the response time under steam medium,the simulation analysis and test of response time measurement under steam medium based on 11 kinds of working conditions are researched.Through the simulation,the influence of different steam media conditions on the temperature sensor response time and the change rule are researched.Combined with 11 kinds of working conditions of the test results data,the actual steam medium under the influence of various combinations of factors under the dynamic response of the temperature sensor results can be taken out.The research has the practical guidance significance,can promote the final design of the protection function curing.The research can provide certain theoretical reference for nuclear power engineering.
Nuclear power plantsSteam mediumTemperature sensorResponse timeDifferent measurement conditions