首页|CoCrNi中熵合金在不同浓度NH4Cl溶液中的腐蚀行为研究

CoCrNi中熵合金在不同浓度NH4Cl溶液中的腐蚀行为研究

扫码查看
通过电化学测试、统计学分析和浸泡腐蚀实验系统地研究了等原子CoCrNi中熵合金(MEA)在不同浓度NH4Cl溶液中的腐蚀行为及机理.结果表明,随着NH4Cl浓度的增加,MEA的腐蚀电位(Ecorr)负移,维钝电流密度(Ip)增大,腐蚀速率增加,合金的耐腐蚀性能降低.当NH4Cl浓度为3%和8%时,阳极曲线出现了明显的活化-钝化过渡区,意味着合金钝性降低.此外,随着NH4Cl浓度的增加,MEA表面钝化膜的缺陷密度明显增加,钝化膜的厚度减薄,稳定性降低,这削弱了膜对合金的保护能力.NH4+和Cl-的共同作用促进了亚稳态点蚀的形核和发展,且在高浓度的NH4Cl溶液中,亚稳态点蚀难以再钝化,容易发展为稳态点蚀.MEA腐蚀形态主要为点蚀.
Corrosion Behavior of Medium Entropy CoCrNi-alloy in NH4Cl Solutions
The corrosion behavior and mechanism of medium entropy equiatomic CoCrNi alloy(MEA)in various NH4Cl solutions(i.e.,with 1%,3%and 8%NH4Cl)were systematically studied by elec-trochemical test,statistical analysis,and immersion corrosion test.The results show that with the in-crease of NH4Cl concentration,the corrosion potential(Ecorr)of the MEA shifts negatively,the passive cur-rent density(/p)increases,and the corrosion rate rises,indicating that the corrosion resistance of the al-loy decreases.When the concentrations of NH4Cl solution are 3%and 8%,the anodic polarization curve displays a clear active-passive transition zone,which means that the passivity of the MEA is reduced.In addition,as NH4Cl concentration increases,the defect density within the passivation film on the MEA in-creases significantly,the thickness of the film decreases,and its stability declines,which weakens the protection ability of the film.The combined effect between NH4+and Cl-promotes the nucleation and de-velopment of metastable pitting corrosion,while in the high concentration of NH4Cl solution,the metasta-ble pits are difficult to be re-passivated,and easy to develop into steady pits.In general,the main corro-sion form of the MEA is pitting corrosion.

MEAcorrosion behaviormetastable pitting corrosionpassive film

张成龙、张斌、朱敏、袁永锋、郭绍义、尹思敏

展开 >

浙江理工大学机械工程学院 杭州 310018

北京中科科仪股份有限公司 北京 100190

中熵合金 腐蚀行为 亚稳态点蚀 钝化膜

浙江省自然科学基金浙江理工大学基本科研业务费专项

LY18E01000422242293-Y

2024

中国腐蚀与防护学报
中国腐蚀与防护学会 中国科学院金属研究所

中国腐蚀与防护学报

CSTPCD北大核心
影响因子:0.819
ISSN:1005-4537
年,卷(期):2024.44(3)