Research on solving the problem of high running current of compressor based on 8D method
In order to solve the problem of high operating current of the compressor complained by customers(15.3A),the operating current is kept in the normal range(6-8A),and its effect is fully exerted within the life range.For this reason,the 8D method was adopted in this paper to set up an 8D team,from the detailed description of the problem,temporary containment measures,identification of the root cause,deployment of permanent corrective measures,verification of corrective measures and other stages of analysis and deployment,to add a visual detection system to the compressor production line,while optimizing the final detection parameters of the production line,to solve the problem of excessive compressor running current.