摘要

采用聚乙烯醇-海藻酸钠(PVA-SA)包埋材料固定短程硝化活性污泥在连续流AO(Anaerobic/Oxic)反应器中处理生活污水并实现稳定的短程硝化.利用响应曲面法,对水力停留时间(HRT)、内循环比以及填充率等参数进行研究,探讨了对亚硝酸盐积累率(NAR)和总氮去除率(NRE)的影响,并成功建立了二次回归模型.结果表明,控制参数HRT为 6.43h,内循环比为 2.93,好氧段填充率为 25%,此时NAR和NRE效果最佳,分别达到 86.22%和 86.56%,表明该工艺具有良好的脱氮性能.此外,还通过活死细菌及原位荧光杂交(FISH)发现,活菌主要分布在颗粒表面0~500µm范围内,死菌分布在0~300µm范围内,并随着深度增加荧光强度逐渐降低.最后,16S rRNA 测序结果表明,长期运行的包埋颗粒相比于短程硝化活性污泥中 Nitrosomonas 的相对丰度由0.013%增加到 5.02%,Nitrospira由 0.055%增加到 1.99%,硝化细菌中亚硝酸氧化细菌(NOB)的比例被降低,而氨氧化细菌(AOB)的比例升高,促进了短程硝化脱氮效果的稳定.

Abstract

Partial nitrification activated sludge immobilized with polyvinyl alcohol-sodium alginate(Polyving Akohol-Sodium Alginate,PVA-SA)was used to treat domestic wastewater and achieve stable partial nitrification in a continuous flow AO(Anaerobic/Oxic)reactor.Using the response surface method,the effects of hydraulic retention time(HRT),internal recirculation ratio and filling rate on nitrite accumulation ratio(NAR)and total nitrogen removal nitrogen removal efficiency(NRE)were investigated,and a quadratic regression model was successfully established.The results showed that the system had the best performance in nitrogen removal with NAR and NRE reaching 86.22%and 86.56%when HRT,internal recirculation ratio and filling rate of aerobic section were controlled as 6.43h,2.93,and 25%,respectively.In addition,it was observed by live and dead bacteria and Fluorescence In Situ Hybridization(FISH)that the live cells were mainly distributed in the range of 0~500µm on the surface of the particles,while the dead bacteria were distributed in the range of 0~300µm.FISH fluorescence was gradually decreased in intensity with the increase of depth.Finally,16S rRNA sequencing results showed that the relative abundance of Nitrosomonas increased from 0.013%to 5.02%and Nitrospira increased from 0.055%to 1.99%in the immobilized particles of the long-term run compared with that of the partial nitrification activated sludge.The proportion of NOB in the nitrifying bacteria was reduced,while the proportion of AOB was increased,which contributed to the stabilization of nitrogen removal effect of partial nitrification.This study provides a promising technology for the engineering application of partial nitrification in municipal wastewater plants.

关键词

PVA-SA/短程硝化/生物脱氮/响应曲面法/微生物群落结构

Key words

PVA-SA/partial nitrification/biological nitrogen removal/response surface methodology/microbial community structure

引用本文复制引用

基金项目

北京市自然科学基金面上项目(8222039)

中建一局科技研发计划资助(KJYF-2022-09)

国家自然科学基金青年科学基金(52100022)

出版年

2024
中国环境科学
中国环境科学学会

中国环境科学

CSTPCDCSCDCHSSCD北大核心
影响因子:2.174
ISSN:1000-6923
参考文献量34
段落导航相关论文