中国化学快报(英文版)2024,Vol.35Issue(1) :446-450.DOI:10.1016/j.cclet.2023.108462

Distance-based α-amylase biosensor fabricated with amylopectin-coated mesoporous membrane

Binglu Zhao Mashooq Khan Yulin Liu Wenjun Tai Chongyang Mu Wenli Wu Mei Zhao Yaohong Ma Li Yu Jin-Ming Lin Qiongzheng Hu
中国化学快报(英文版)2024,Vol.35Issue(1) :446-450.DOI:10.1016/j.cclet.2023.108462

Distance-based α-amylase biosensor fabricated with amylopectin-coated mesoporous membrane

Binglu Zhao 1Mashooq Khan 1Yulin Liu 2Wenjun Tai 3Chongyang Mu 3Wenli Wu 1Mei Zhao 1Yaohong Ma 4Li Yu 3Jin-Ming Lin 5Qiongzheng Hu1
扫码查看

作者信息

  • 1. Qilu University of Technology(Shandong Academy of Sciences),Shandong Analysis and Test Center,Ji'nan 250014,China;School of Pharmaceutical Sciences,Qilu University of Technology(Shandong Academy of Sciences),Ji'nan 250014,China
  • 2. Qilu University of Technology(Shandong Academy of Sciences),Shandong Analysis and Test Center,Ji'nan 250014,China
  • 3. Key Laboratory of Colloid and Interface Chemistry,Shandong University,Ministry of Education,Ji'nan 250100,China
  • 4. Key Laboratory for Biosensors of Shandong Province,Biology Institute,Qilu University of Technology(Shandong Academy of Sciences),Ji'nan 250353,China
  • 5. Beijing Key Laboratory of Microanalytical Methods and Instrumentation,MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology,Department of Chemistry,Tsinghua University,Beijing 100084,China
  • 折叠

Abstract

Paper-based biosensors are widely employed in point-of-care testing(POCT)due to their convenience,portability,low cost,and ease of use.This study reports an integrated distance-based paper biosensor fabricated with a mesoporous membrane coated with stimuli-responsive polymer.The detection of α-amylase(AMY)using amylopectin-coated mesoporous membrane is demonstrated as an example.After introducing the AMY solution,it is observed that the aqueous solution flows along the paper strip due to AMY-catalyzed hydrolysis of amylopectin.The flow distance is proportional to the concentration of AMY with a detection limit as low as 4 mU/mL.In addition,the detection of AMY is demonstrated in human serum.Furthermore,the inhibitory effect of acarbose on AMY is evaluated.This reagent-free and dispos-able biosensor allows single-step rapid detection of the analyte.This approach is very promising for the development of user-friendly,equipment-free,and cost-effective biosensors with remarkable sensitivity and excellent selectivity for disease diagnosis and hypoglycemic drug screening.

Key words

Paper biosensor/α-Amylase/Stimuli-responsive polymer/Mesoporous membrane/Distance/Point-of-care testing

引用本文复制引用

基金项目

国家重点研发计划(2021YFB3201200)

国家重点研发计划(2021YFB3201202)

山东省"泰山学者"岗位项目(tsqn201812088)

山东省自然科学基金(ZR2022YQ12)

Shandong Scientific and Technical Small and Mediumsized Enterprises Innovation Capacity Improvement Project(2022TSGC2533)

Science,Education and Industry Integration Innovation Pilot Project from Qilu University of Technology(Shandong Academy of S(2022JBZ02-04)

出版年

2024
中国化学快报(英文版)
中国化学会

中国化学快报(英文版)

CSTPCDCSCD
影响因子:0.771
ISSN:1001-8417
参考文献量1
段落导航相关论文