迪瑞尿液检验工作站和显微镜镜检在尿常规检验中的应用效果观察
Observation on the effect of the application of Diri urine test workstation and microscope in routine urine test
林萍1
作者信息
- 1. 龙泉市人民医院 检验科,浙江 龙泉 323700
- 折叠
摘要
目的 观察显微镜镜检和迪瑞尿液检验工作站(由FUS-200全自动尿有形成分分析仪和H-800全自动尿液分析仪组成)在尿常规检验当中的应用效果.方法 按照随机的原则选取龙泉市人民医院住院患者的尿液标本378例,分别采用3种检验方法进行尿常规检验,检验项目主要为白细胞(WBC)和红细胞(RBC),对比检验结果.结果 H-800全自动尿液分析仪:RBC敏感性为94.3%,特异性为93.5%,WBC敏感性为85.4%,特异性为99.4%;FUS-200全自动尿有形成分分析仪:RBC敏感性为85.7%,特异性为98.4%,WBC敏感性为92.7%,特异性为99.4%.结论 在尿常规检验时,需要将3种检验方式相结合进行综合分析,才能得到准确的检验结果,为临床诊治提供可靠的依据.
Abstract
Objective To observe the effect of the application of Diri urine test workstation(consisting of FUS-200 urine analyzer and H-800 automatic urine analyzer) and microscope in routine urine test. Methods 378 cases of urine samples of patients in Longquan municipal people's hospital were selected randomLy. Urine routine test were carried out by three methods. The main test items were white blood cells (WBC) and red blood cell (RBC), the test results were compared. Results H-800 automatic urine analyzer: the sensitivity of RBC was 94.3%, the specificity was 93.5%, the sensitivity of WBC was 85.4%, the specificity was 99.4%; FUS-200 urine analyzer: the sensitivity of RBC was 85.7%, the specificity was 98.4%, the sensitivity of WBC was 92.7%, the specificity was 99.4%. Conclusion In order to get the most accurate results, we need to make a comprehensive analysis of the three kinds of test methods in order to provide a reliable basis for clinical diagnosis and treatment.
关键词
迪瑞尿液检验工作站/显微镜镜检/尿常规检验Key words
Dirui urine test workstation/microscopy/urine routine test/effect引用本文复制引用