Determination of 10 antiviral drugs in compound feed by ultra-high performance liquid chromatography tandem mass spectrometry
A method for detecting 10 kinds of anti-viral drugs in compound feed was established by ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The samples were extracted by 1%formic acid and acetonitrile solution and purified by PRIME HLB solid phase extraction column.The 10 kinds of anti-viral drugs were separated by PC HILIC column and gradiently eluted using acetonitrile and 10 mmol/L ammonium acetate solution(containing 0.2%formic acid).The quantitative analysis was conducted using the matrix matching external standard method.The results showed that the calibration curves were in good linear relationship in the range of 1.0~100 ng/mL.The recoveries of the 10 kinds of anti-viral drugs at three spiked levels(50,100,500 μg/kg)were 87.5%~106.3%,and the relative standard deviations were 1.2%~10.6%.The detection limit was 20 μg/kg and the quantitative limit was 50 μg/kg.
antiviral drugsultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)solid phase extraction(SPE)compound feed