目的 建立检测重组腺相关病毒9型(recombinant adeno-associated virus type 9,rAAV9)空壳率的阴离子交换高效液相色谱(anion-exchange high-performance liquid chromatography,AEX-HPLC)法,并进行验证.方法 采用基于电荷差异的AEX-HPLC法,通过对流动相洗脱梯度、流动相pH、色谱柱柱温、流速、样品浓度、进样体积和荧光检测器检测波长进行优化,建立检测rAAV9空壳与实心病毒比例的方法,并对方法的专属性、线性、检测限、定量限、精密度和准确度进行验证,确认方法可行性.结果 利用CIMac AAV full/empty-0.1 mL分析柱,以20 mmol/L 1,3-二[三(羟甲基)甲氨基]丙烷(BIS-Tris propane,BTP)为流动相A,20 mmol/L BTP+1 mol/LNaCl为流动相B进行梯度洗脱,流动相pH均为9.0,柱温20 ℃,流速1 mL/min,样品浓度4 × 1012 vg/mL,进样体积10 µL,激发波长为280 nm,发射波长为330 nm,可实现rAAV9空壳与实心病毒的基线分离及定量检测.方法 验证结果表明,制剂缓冲液无干扰,专属性较好;rAAV9在(1.6~8)× 1012vg/mL范围内线性关系良好,r=0.993;检测限为5× 1010vg/mL,定量限为1 × 1011vg/mL;重复性和中间精密度RSD分别为2.95%和2.10%;准确率均不低于80%.结论 建立了一种高灵敏度且可快速检测rAAV9空壳与实心病毒比例的AEX-HPLC法,可用于基因治疗产品空壳率的分析及质量控制.
Development and verification of anion-exchange high-performance liquid chromatography for determination of empty capsid ratio in recombinant adeno-associated virus type 9
Objective To develop and verify an anion-exchange high-performance liquid chromatography(AEX-HPLC)method for the determination of empty capsid ratio of recombinant adeno-associated virus type 9(rAAV9).Methods AEX-HPLC based on the differences in surface charge was used to establish a method for detecting the ratio of empty and full cap-sid rAAV9 by optimizing the elution gradient of mobile phase,pH,column temperature,flow rate,sample concentration,injection volume and detection wavelength of fluorescence detector.The specificity,linearity,limit of detection(LOD),limit of quantitation(LOQ),precision and accuracy of the method were verified to confirm the feasibility.Results Using a CIMac AAV full/empty-0.1 mL column,20 mmol/L BIS-Tris propane(BTP)as mobile phase A and 20 mmol/L BTP+1 mol/L NaCl as mobile phase B,gradient elution was performed with pH of 9.0,column temperature of 20 ℃,flow rate of 1 mL/min,sample concentration of 4 × 1012 vg/mL,injection volume of 10 µL,excitation wavelength of 280 nm and emission wavelength of 330 nm,which realised the baseline isolation and quantitative detection of empty and full capsid rAAV9.The verification results of the method showed that the preparation buffer had no interference with good specificity;rAAV9 showed a good linear relationship in the range of(1.6-8)× 1012vg/mL,r=0.993;the LOD was 5 × 1010vg/mL,and the LOQ was 1 × 1011 vg/mL;the RSD of repeatability and intermediate precision were 2.95%and 2.10%,respectively;the accuracy rates were not less than 80%.Conclusion A highly sensitive and rapid AEX-HPLC method for determination of the ratio of empty capsid to full capsid rAAV9 was developed,which could be used for the analysis of empty capsid rate and quality control in gene therapy products.

Recombinant adeno-associated virus(rAAV)Gene therapyAnion-exchange high-performance liquid chroma-tography(AEX-HPLC)Empty capsid virusFull capsid virusQuality control

史新昌、王凤阳、刘亚辉、周勇、刘宾

展开 >

中国食品药品检定研究院国家卫生健康委员会生物技术产品检定方法及其标准化重点实验室国家药品监督管理局生物制品质量研究与评价重点实验室,北京 100050

上海泰昶生物技术有限公司,上海 201413

上海天泽云泰生物医药有限公司,上海 201203

重组腺相关病毒 基因治疗 阴离子交换高效液相色谱法 空壳病毒 实心病毒 质量控制

国家重点研发计划国家重点研发计划

2023YFC34033052021YFFO600804

2024

中国生物制品学杂志
中华预防医学会,长春生物制品研究所有限责任公司

中国生物制品学杂志

CSTPCD
影响因子:0.417
ISSN:1004-5503
年,卷(期):2024.37(5)
  • 27