Effect analysis of routine auxiliary function exercise combined with rehabilitation robotic gloves to prevent complications of midline catheters
Objective To explore the effect of routine auxiliary function exercise combined with rehabilitation robotic gloves to prevent complications of midline catheters.Methods 52 patients requiring midline catheters were selected and divided into a control group and an observation group according to random number table method,with 26 patients in each group.The control group received routine auxiliary function exercise,and the observation group received routine auxiliary function exercise combined with rehabilitation robotic gloves.The coagulation function[thrombin time(TT),prothrombin time(PT),fibrinogen(FIB),D-dimer(D-D)],functional training compliance,complications and satisfaction were compared between the two groups.Results Compared with before intervention,the serum PT,TT,FIB and D-D levels decreased in both groups after intervention;the serum TT,FIB and D-D levels in the observation group were lower than those in the control group after intervention;the observation group had higher PT than that in the control group after intervention;the difference was statistically significant(P<0.05).After intervention,the scores of exercise compliance,monitoring compliance,active help seeking compliance,precautions compliance and total score of the observation group were(10.34±1.23),(5.11±0.64),(8.58±1.24),(10.81±1.33)and(34.84±3.48)points,which were higher than(5.47±0.78),(3.72±0.47),(5.67±0.75),(6.57±0.82)and(21.43±4.54)points in the control group,and the difference was statistically significant(P<0.05).During intervention,the complication rate of 3.85%in the observation group was lower than 34.62%in the control group,and the difference was statistically significant(P<0.05).After intervention,the total satisfaction of the observation group was 96.15%,which was higher than 69.23%of the control group,and the difference was statistically significant(P<0.05).Conclusion Routine auxiliary function exercise combined with rehabilitation robotic gloves can effectively improve the coagulation function of patients with midline catheters,improve the exercise compliance,monitoring compliance,active help seeking compliance and precautions compliance of patients,reduce the occurrence of complications,and improve patients'satisfaction with nursing.
Midline cathetersRoutine auxiliary function exerciseRobotic glovesCoagulation functionComplications