首页|X射线辐射对埃克替尼大鼠体内药动学的影响

X射线辐射对埃克替尼大鼠体内药动学的影响

扫码查看
目的:建立测定大鼠血浆中埃克替尼浓度的LC-MS/MS定量分析方法,研究X射线辐照对埃克替尼在大鼠体内药动学的影响并探究其RT-PK(radiotherapy-pharmacokinetics)现象.方法:将SD大鼠随机分为对照组和辐射组,辐射组分别进行不同剂量、不同次数及不同部位的X射线照射,恢复24 h后和对照组同时灌胃给予15mg·kg-1埃克替尼,采集不同时间点大鼠血浆.用LC-MS/MS定量分析方法测定大鼠血浆样品中埃克替尼的浓度,计算药动学参数.结果:测定大鼠血浆中埃克替尼浓度的LC-MS/MS方法通过了严格的方法学验证.大鼠灌胃给予埃克替尼后,其药动学实验结果显示,单次照射后随辐射剂量增加,胸腔辐射组血药浓度-时间曲线下面积(AUC)呈增加趋势,但无统计学差异;连续5 d胸腔照射(RT2Gy)后埃克替尼AUC显著下降;单次腹腔照射(RT5Gy)后埃克替尼的达峰浓度(Cmax)显著下降,其他药动学参数无显著改变.结论:通过验证的LC-MS/MS方法快速、准确、灵敏,可应用于测定大鼠血浆埃克替尼的浓度.药动学吸收实验结果提示单次X射线辐射对埃克替尼药动学影响不显著,多次胸腔照射可能导致该药物血浆暴露量降低,提示临床应根据实际情况合理调整埃克替尼的用量.
Effect of X-ray on the pharmacokinetics of icotinib in vivo
Objective:To establish a quantitative LC-MS/MS method for determination of icotinib concentration in rat plasma to investigate the effect of thoracic X-ray irradiation on the pharmacokinetics of icotinib in rats and investigate whether there is radiotherapy-pharmacokinetics(RT-PK)phenomenon for icotinib.Methods:SD rats were randomly divided into control and radiation groups.The radiation groups were irradiated with different dosages of X-ray for different times or at different sites.After 24 hours of recovery,15 mg·kg-1 of icotinib was given to rats by gavage and plasma was collected at different time points.The concentrations of icotinib in the plasma samples were determined by LC-MS/MS,and the pharmacokinetic parameters were calculated.Results:The LC-MS/MS method for determination of icotinib in rat plasma was validated successfully.The results of the pharmacokinetic experiments of icotinib showed that the aera under the curve(AUC)of icotinib of the thoracic radiation group increased with increasing dose of radiation after single irradiation,but there was no statistical difference.The icotinib AUC decreased significantly in the thoracic radiation group(RT2Gy)after radiation for five consecutive days.The Cmax of icotinib decreased significantly in the abdominal irradiation group(RT5Gy),but the other PK parameters did not change significantly.Conclusion:The validated LC-MS/MS method is rapid,accurate,and sensitive and can be applied to determine the concentration of icotinib in rat plasma.The results of pharmacokinetic experiments suggest that the effect of single X-ray radiation on the PK of icotinib is not significant,but multiple thoracic radiation may lead to a decrease in plasma exposure.The dosage of icotinib should be rationally adjusted in clinical therapy.

icotinibradiationpharmacokineticsliquid chromatography-mass spectrometry

王玲梅、杨凡、梁博涵、张爱杰、王伟占、刘鉴峰、董世奇、樊慧蓉

展开 >

中国医学科学院放射医学研究所,天津 300192

中国医学科学院创新药物放射性药代研究重点实验室,天津 300192

天津市第四中心医院心内科,天津 300142

埃克替尼 辐射 药动学 液相色谱-质谱联用

国家自然科学基金国家自然科学基金中国医科院医学与健康科技创新工程项目中国医科院医学与健康科技创新工程项目

82204509821042842022-I2M-2-0022021-I2M-1-058

2024

中国新药杂志
中国医药科技出版社 中国医药集团总公司 中国药学会

中国新药杂志

CSTPCD北大核心
影响因子:1.039
ISSN:1003-3734
年,卷(期):2024.33(12)