首页|左束支起搏动物模型建立及组织学和电生理参数评估

左束支起搏动物模型建立及组织学和电生理参数评估

扫码查看
目的 建立左束支起搏(LBBP)模型,明确LBBP起搏电极植入部位与起搏参数的相关性。方法 选取健康比格犬5只。在三维标测系统的指导下建立犬LBBP模型。术后对犬心脏行大体染色和组织病理学检测明确起搏电极位置,结合术中记录的心电图及起搏参数,证实LBBP时起搏电极植入部位与起搏参数的相关性。结果 5只犬均成功实现LBBP模型建立,并标测到His束及左束支(LBB)电位。起搏阈值为(0。80±0。19)V/0。5 ms;R波振幅为(10。6±3。5)mV;刺激逆传至His束时间(Stim-Retro-His)为(15。5±3。0)ms;刺激至左室达峰时间(Stim-LVAT)为(47。8±5。5)ms;起搏QRS波时限为(95。0±8。9)ms;刺激到QRS波结束的时间(Stim-QRS end)为(97。0±9。2)ms。间隔心肌不应期为(268。0±10。5)ms,LBB不应期为(310。0±15。5)ms。所有电极头端穿过室间隔到达或靠近左侧传导系统,平均室间隔厚度为(11。8±1。3)mm,平均电极间隔深度为(11。4±2。5)mm。结论 本研究成功建立LBBP动物模型,同时证实植入过程中Stim-Retro-His≤20 ms和Stim-LVAT突然缩短≥10 ms可作为LBB夺获的重要指标。
Establishment of left bundle branch pacing animal model and evaluation of of histology and electrophysiological parameters
Objective To establish a left bundle branch pacing (LBBP)model and determine the correlation be-tween the implantation of LBBP pacing electrodes and pacing parameters. Methods Five healthy beagles were se-lected for the study.The LBBP model in canines was established under the guidance of three-dimensional mapping system.Gross staining and histopathological examination of the canine hearts were conducted to determine the loca-tion of the pacing electrodes after procedure.The correlation between the implantation site and pacing parameters during LBBP was confirmed. Results All five canines successfully achieved the establishment of the LBBP model,and the potential of his bundle and left bundle branch(LBB)was detected.Pacing parameters recorded during the procedure were as follows:pacing threshold was (0.80±0.19)V/0.5ms;R-wave amplitude was (10.6±3.5)mV;time from stimulation retrograde to His bundle activation (Stim-Retro-His)was (15.5±3.0)ms;time from stimu-lation to left ventricular activation (Stim-LVAT )was (47.8±5.5)ms;pacing QRS duration was (95.0±8.9)ms;time from stimulation to QRS end (Stim-QRSend)was (97.0±9.2)ms.The interval myocardial refractory period was (268.0±10.5)ms,and the LBB refractory period was (310.0±15.5)ms.All electrode tips passed through the interventricular septum to reach or approach the left conduction system,with an average interventricular septum thickness of(11.8±1.3)mm,and the electrode depth of (11.4±2.5)mm. Conclusion This study successfully established a LBBP animal model.The relationship between the implantation site and pacing was confirmed that Stim-Retro-His≤20 ms and a sudden shortening of Stim-LVAT by ≥10 ms could be used as important criteria to confirm LBB capture.

CardiologyLeft bundle branch pacingHistological evaluationElectrophysiological parametersElectrocardiogramCanine model

孙田宏、许静、卢凤民、李丽华、何乐、张帆、樊少博、马薇

展开 >

天津大学胸科医院 天津市心血管病研究所,天津300222

心血管病学 左束支起搏 组织学评估 电生理参数 心电图 犬模型

2024

中国心脏起搏与心电生理杂志
中国生物医学工程学会 武汉大学人民医院

中国心脏起搏与心电生理杂志

CSTPCD
影响因子:0.563
ISSN:1007-2659
年,卷(期):2024.38(6)