首页|心电共模抑制比自动化测试系统的研制

心电共模抑制比自动化测试系统的研制

Development of ECG Common Mode Rejection Ratio Automatic Test System

扫码查看
为了全面地满足不同心电专用标准中共模抑制比的测试要求,该文研究设计了一种心电共模抑制比自动化测试系统.系统硬件部分主要由测试信号发生模块、自动化控制网络(包括阻容网络控制模块和极化电压控制模块)以及噪声电平切换模块组成,软件部分实现了自动化控制的驱动和用户交互功能.实验结果表明:该系统稳定可靠,自动化程度高,可满足不同心电专用标准的测试要求,具有较好的应用前景.
To comprehensively meet the test requirements for the common mode rejection ratio(CMRR)across different ECG-particular standards,this paper presents the design of an ECG CMRR automatic test system.The hardware component primarily consists of a test signal generation module,an automatic control network(which includes a resistance-capacitance network control module and a polarization voltage control module),and a noise level switching module.The software portion enables automatic control and user interaction.Experimental results indicate that the system is stable,reliable,and highly automated,capable of satisfying the test requirements of various ECG-particular standards,thus demonstrating a promising application prospect.