首页|ICP-MS测定地佐辛注射液中24种元素杂质

ICP-MS测定地佐辛注射液中24种元素杂质

扫码查看
目的:按照ICH Q3D的相关规定,建立ICP-MS法同时测定地佐辛注射液中24种元素杂质含量。方法:将试样溶液经稀释后,通过ICP-MS法进行化学检测分析,再通过加铟、铋为内标的方式进行校正,等离子体输出功率设置为1 550 W,采样深度为5 mm,最大载气量为1。038 L·min-1,冷却气为14 L·min-1,辅助气为0。8 L·min-1,蠕动泵转速为40 r·min-1,进样系统为耐氢氟酸系统,取样圆锥及截取锥的型式为镍圆锥,采样方式为手动,重复3次。结果:24种元素线性均良好(r均大于0。99),平均回收率在80。46%~102。95%之间,重复性均小于10。88%,中间精密度均不大于6。49%。3批地佐辛注射液中24种元素杂质含量结果均符合ICH Q3D要求。结论:方法便捷、快速、灵敏、准确,可用于地佐辛注射液中24种元素含量的检测,可为该注射剂提供更加严格的质量控制依据。
Determination of 24 elemental impurities in dizocine injection by ICP-MS
Objective:To establish a method of inductively coupled plasma mass spectrometry(ICP-MS)for the simultaneous determination of 24 elemental impurities in dizocine injection in accordance with the relevant regula-tions of ICH Q3D.Methods:ICP-MS method was adopted to analyze the sample solutions after being diluted and then corrected by spiking indium and bismuth as internal standards,the plasma output power was set at 1 550 W,the sampling depth was set at 5 mm,the maximum load volume was set at 1.038 L·min-1,the cooling gas was set at 14 L·min-1,the auxiliary gas was 0.8 L·min-1,the peristaltic pump speed was 40 r·min-1,the injection system was hydrofluoric acid resistant system,the sampling cone and the pattern of the intercept cone were nickel cone and the sampling mode was manual and repeated 3 times.Results:All 24 elements were linear(all r were more than 0.99),the average recoveries were between 80.46%and 102.95%,the repeatability were less than 10.88%,and the intermediate precision were not more than 6.49%.The results of 24 elemental impurities in 3 different batches of dizocine injection met requirements of ICH Q3D.Conclusion:The ICP-MS method is conven-ient,rapid,sensitive and accurate,and can be used to detect the concentrations of 24 metal elements in dizocine injection,which may provide a basis for more strict quality management of the injection.

dizocine injectionICH Q3DICP-MSelemental impuritiesquality control

黄小琴、陶逸波

展开 >

泰州市药品检验院,江苏泰州 225300

南京中医药大学,江苏泰州 225300

地佐辛注射液 ICH Q3D 电感耦合等离子体质谱法 元素杂质 质量控制

2024

中国药品标准
国家药典委员会

中国药品标准

影响因子:0.372
ISSN:1009-3656
年,卷(期):2024.25(2)