Validation of bacterial endotoxin test for aluminum hydroxide adjuvant by TAL method
Objective:To establish a TAL gel-clot bacterial endotoxin test for aluminum hydroxide adjuvant.Methods:According to the bacterial endotoxin test in general chapter 1143 of the Chinese Pharmacopoeia 2020,pre-interference test was performed using 3 types of buffer solutions and Ca-Mg additive by orthogonal design.The interference test and sample preparation validation were carried out using different batches of aluminum hydroxide adjuvant from 2 TAL manufacturers.Results:No interference was obtained through pre-interference test.Under the validated conditions,aluminum hydroxide adjuvant combined with phosphate buffered saline and Ca-Mg additive was employed to remove interference in bacteria endotoxin test.Conclusion:The established TAL gel-clot method is applicable to bacterial endotoxin test for aluminum hydroxide adjuvant.