某综合医院已正式运营5年有余,医院空调系统设计和施工阶段考虑不全面的问题逐步凸显.该文列举了空调系统设计思路以及日常运行中遇到的过渡季节内外区冷热不均,发热门诊空调选型偏小,某些机组安装位置不便于维修与更换,某些区域空调设置不合理等问题,并给出建议或解决方案.

Abstract

A general hospital has been officially operated for more than 5 years,and the problems of incomplete consideration in the design and construction stage of the hospital air conditioning system gradually highlighted.This paper listed the design ideas of the air conditioning system and the problems encountered in daily operation,such as uneven cooling and heating in the transition season,small selection of air conditioning in the fever clinic,inconvenient installation position for maintenance and replacement of some units,and unreasonable setting of air conditioning in some areas,and gave suggestions or solutions.

关键词

医院/空调系统/新风系统/水系统

Key words

hospital/air conditioning system/fresh air system/water system