首页|一款无创连续血压测量设备研制及其准确性验证

一款无创连续血压测量设备研制及其准确性验证

Development and accuracy verification of a continuous non-invasive blood pressure measurement device/

扫码查看
目的:研制一款无创连续血压测量设备NC-BPM型并验证其监测血压的准确性.方法:研制一款NC-BPM型无创连续血压测量设备(简称NC-BPM),整套设备系统主要由指套传感器、信号采集和压力控制单元、高度校正系统和主机4个模块组成.使用欧姆龙J760电子血压计(简称J760)和CNAP Monitor 500连续无创血压监测系统(简称CNAP Monitor 500)作为监测血压准确性验证的参考血压计,按照美国电气和电子工程师协会(IEEE)有关可穿戴无袖带血压测量装备标准测试流程,分别测量25名受试者静态期、血压变化期和校准后期3个阶段的血压,验证NC-BPM测量血压的准确性.结果:使用NC-BPM与CNAP Monitor 500均采集到13 753个数据点,两种仪器测得收缩压(SBP)、舒张压(DBP)及平均血压(MAP)具有高度相关性(r=0.96、0.97、0.98,P<0.05);欧姆龙J760采集到379个数据点,NC-BPM与欧姆龙J760测得SBP和DBP数据亦有高度相关性(r=0.98、0.95,P<0.05).按照英国高血压协会(BHS)和美国医疗仪器促进协会(AAMI)标准的等级评价,NC-BPM与CNAP Monitor500的SBP差值在0~5 mmHg、0~10 mmHg和0~15 mmHg范围内的占比分别为85.01%、97.60%和99.47%,DBP占比分别为84.34%、99.85%和100%,MAP占比分别为92.66%、99.72%和99.96%,三者均属BHS标准A级;两种仪器测量的指动脉SBP、DBP和MAP压差值分别为(0.67±5.07)mmHg、(2.43±2.87)mmHg和(1.43±2.89)mmHg,均在AAMI标准(5±8)mmHg范围内.NC-BPM与欧姆龙J760的SBP差值0~5 mmHg、0~10 mmHg和0~15 mmHg范围内占比分别为79.95%、97.36%和100%,DBP占比分别为89.71%、99.74%和100%,两者均属BHS标准A级;两种仪器测量的肱动脉收缩压、舒张压差值分别为(1.57±4.18)mmHg、(0.57±5.20)mmHg,均在AAMI标准(5±8)mmHg范围内.结论:NC-BPM设备已通过了IEEE标准下AAMI标准的第一阶段临床试验,可进行下一阶段临床验证试验.
Objective:To develop a continuous non-invasive blood pressure measurement device(NC-BPM)and verify the accuracy of that in monitoring blood pressure.Methods:A NC-BPM type of non-invasively continuous blood pressure measurement device(NC-BPM for short)was developed.The entire system consisted of four modules included one sensor which shape was finger cot,one unit of signal acquisition and pressure control,one calibration system for height and one host.The Omron J760 electronic sphygmomanometer(J760)and the CNAP Monitor500 continuous non-invasive blood pressure monitoring system(CNAP Monitor500)were used as the reference sphygmomanometer of verifying accuracy of the monitored blood pressure.The blood pressures of 25 subjects at three stages included static stage,blood pressure change stage and stage post calibration were respectively measured according to the standard test procedure of wearable sleeveless blood pressure measurement device of Institute of Electrical and Electronics Engineers(IEEE).Results:Both NC-BPM and CNAP Monitor500 collected 13753 data points,and there were high correlation in systolic blood pressure(SBP),diastolic blood pressure(DBP)and mean blood pressure(MAP)between the two devices(r=0.96,0.97,0.98,P<0.05).A total of 379 data points were collected by Omron J760,and there were high correlation in SBP and DBP between NC-BPM and Omron J760(r=0.98,0.95,P<0.05).According to the standards of British Hypertension Society(BHS)and the American Association for the Advancement of Medical Instrumentation(AAMI)to conduct grade evaluation,and the proportions of the SBP differences between NC-BPM and CNAP Monitor500 within the ranges of 0~5 mmHg,0~10 mmHg and 0~15 mmHg were respectively 85.01%,97.60%and 99.47%,and the proportions of the DBP differences between them within the three ranges were respectively 84.34%,99.85%and 100%,and the proportions of the MAP differences were respectively 92.66%,99.72%and 99.96%,all of which belonged to BHS grade A.The pressure difference values of measured SBP,DBP and MAP between the two devices were respectively(0.67±5.07)mmHg,(2.43±2.87)mmHg and(1.43±2.89)mmHg,which were within the(5±8)mmHg of AAMI standard range.The proportions of the SBP differences between NC-BPM and Omron J76 within the ranges of 0~5 mmHg,0~10 mmHg and 0~15 mmHg were respectively 79.95%,97.36%and 100%,and the proportions of the DBP differences between them within the three ranges were respectively 89.71%,99.74%and 100%,all of which belonged to BHS grade A.The difference values of systolic and diastolic blood pressures of brachial artery between the two devices were respectively(1.57±4.18)mmHg and(0.57±5.20)mmHg,which were within the(5±8)mmHg of AAMI standard range.Conclusion:The NC-BPM device has passed the first stage of clinical trials in accordance with IEEE standards,which can proceed to the next stage of clinical verification trials.

Non-invasionContinuous Blood pressure measurementAccuracyBlood pressureVerification trialVolume-clamping technique

吴燕、吴庞、何攀、沈建、方震、韩宝石、汪奇

展开 >

解放军医学院 北京 100853

解放军总医院第六医学中心心血管病医学部 北京 100037

解放军总医院京北医疗区清河门诊部 北京 100085

中国科学院空天信息创新研究院 北京 100094

中国科学院大学 北京 100049

展开 >

无创 连续血压测量 准确性 验证试验 体积钳制技术

国家重点研发计划解放军总医院军事医学科研创新转化项目

2020YFC1512305CX19014

2024

中国医学装备
中国医学装备协会

中国医学装备

CSTPCD
影响因子:0.882
ISSN:1672-8270
年,卷(期):2024.21(3)
  • 18