为研究宽高比对深井立式空间火灾烟气蔓延的影响,以某深井立体车库为原型,建立7 种不同宽高比的深井立式空间物理模型,分析不同宽高比下深井立式空间内的火灾烟气蔓延特性,研究井内烟气速度场和温度的变化规律.研究结果表明:随着宽高比的降低,烟气蔓延至井口的平均速度呈减小趋势,烟气充满深井的时间逐渐缩短;120 s前速度场整体较为规则,烟气竖向流速随着深井宽高比的减小整体呈减小趋势;存在1 个临界宽高比,当火源位于深井底部时,井口处刚好只有热烟气的流出,模拟得到的临界宽高比位于0.3~0.36 之间;在相同宽高比下,深井中心线上的温度随火源上方高度增加逐渐下降;深井中心线上相同高度处的温度随深井宽高比的减小而上升.研究结果可为深井立式空间的消防设计提供科学参考.
Numerical simulation analysis on smoke spread of fire in deep vertical space with different aspect ratios
To study the influence of aspect ratio on smoke spread of fire in the deep vertical spaces,seven physical models of deep vertical space with different aspect ratios were established based on the prototype of a deep vertical garage.The smoke spread characteristics of fire in the deep vertical space with different aspect ratios were analyzed,and the variation laws of smoke velocity field and temperature in the deep vertical space were mastered.The results show that with the decrease of as-pect ratio,the average velocity of smoke spreading to the exit presents a decreasing trend,and the time of smoke filling deep vertical space is shortened gradually.The overall velocity field is relatively regular before 120 seconds,and the vertical veloci-ty of smoke presents a decreasing trend as the aspect ratio of deep vertical space decreases.There is a critical aspect ratio,which means that when the fire source is located at the bottom of deep vertical space,only hot smoke flows out at the exit,and the simulated critical aspect ratio is between 0.3 and 0.36.Under the same simulated critical,the temperature on the center line of deep vertical space decreases gradually with the increase of the height above the fire source.The temperature at the same height along the center line of deep vertical space increases with the decrease of aspect ratio of deep vertical space.The research results can provide scientific reference for fire protection design of deep vertical space.

deep vertical space fireaspect ratiosmoke spreadvelocity fieldnumerical simulation

梁文艳、雷鹏、吕伟

展开 >

武汉理工大学 中国应急管理研究中心,湖北 武汉 430070

武汉理工大学 安全科学与应急管理学院,湖北 武汉 430070

河南省瓦斯地质与瓦斯治理重点实验室,河南 焦作 454000

深井立式空间火灾 宽高比 烟气蔓延 速度场 数值模拟

河南省瓦斯地质与瓦斯治理重点实验室——省部共建国家重点实验室培育基地开放基金项目中央高校基本科研业务费专项资金资助项目

WS2022B06233161001

2024

中国安全生产科学技术
中国安全生产科学研究院

中国安全生产科学技术

CSTPCD北大核心
影响因子:1.119
ISSN:1673-193X
年,卷(期):2024.20(7)