首页|胎儿期脊髓神经管畸形产前超声与胎儿MRI影像的对比分析

胎儿期脊髓神经管畸形产前超声与胎儿MRI影像的对比分析

扫码查看
目的 比较产前超声与胎儿MRI对不同类型胎儿期脊髓神经管畸形(SNTDs)的诊断准确率和诊断优势,并总结多种类型SNTDs的产前超声与胎儿MRI的特征性表现.方法 前瞻性随访2020年7月至2023年2月解放军总医院第一医学中心神经外科医务部门诊接诊的产前诊断考虑为SNTDs、且出生后经脊柱MRI检查确诊的患儿161例,回顾性分析其产前和出生后的影像学资料.以患儿出生后的MRI检查结果为诊断金标准,采用McNemar检验法比较产前超声与胎儿MRI对各类型胎儿SNTDs的诊断准确率.结果 研究共纳入14种胎儿期SNTDs.产前超声对脊柱裂(P=0.001)、椎管内囊肿(P=0.002)、皮毛窦(P=0.002)的诊断准确率(比例)高于胎儿MRI;而对于椎管内脂肪瘤(P<0.001)、脂肪脊膜膨出(P=0.039)的诊断准确率低于胎儿MRI.产前超声诊断节段性脊柱发育不良的准确比例高于胎儿MRI(分别为18/18和7/18);胎儿MRI诊断脂肪脊髓脊膜膨出(4/4对比3/4)、骶尾部发育不良(2/3对比0/3)、脊髓空洞症(2/4对比0/4)、尾端退化综合征(1/1对比0/1)、脊髓脊膜膨出(6/6对比3/6)的准确比例高于产前超声;对于脊膜膨出、终丝紧张、骶尾部畸胎瘤,产前超声与胎儿MRI的诊断准确率(比例)相同.对于各类型胎儿SNTDs,其产前超声和胎儿MRI的表现均有其各自的特征.结论 产前超声与胎儿MRI在诊断胎儿期SNTDs时的优势各异.充分了解SNTDs的产前影像学特征性表现可提高产前诊断准确率.
Comparative analysis of prenatal ultrasonography and fetal MRI of fetal spinal neural tube defects
Objective To compare the diagnostic accuracy and diagnostic advantages of prenatal ultrasound and fetal MRI for different types of fetal spinal neural tube defects(SNTDs),and to summarize the characteristic manifestations of prenatal ultrasound and fetal MRI for various types of SNTDs.Methods We prospectively followed up 161 fetuses admitted to the Neurosurgery Clinic of the First Medical Center of Chinese PLA General Hospital from July 2020 to February 2023 who were considered to have SNTDs in prenatal diagnosis and confirmed by spine MRI examination after birth.A retrospective review of their prenatal and postnatal imaging data was performed.Postnatal MRI examination results were taken as the diagnostic gold standard.The McNemar test was used to compare the diagnostic accuracy of prenatal ultrasound and fetal MRI for various types of fetal SNTDs.Results A total of 14 fetal SNTDs were included in the study.The diagnostic accuracy of prenatal ultrasound for spina bifida(P=0.001),intraspinal cyst(P=0.002)and dermal sinus(P=0.002)was higher than that of fetal MRI,while for intraspinal lipoma(P<0.001)and lipomingocele(P=0.039),the diagnostic accuracy of prenatal ultrasound was lower than that of fetal MRI.Prenatal ultrasound was more accurate in diagnosing segmental spinal dysgenesis than fetal MRI(18/18 vs.7/18);fetal MRI was more accurate than prenatal ultrasound in diagnosing lipomyomeningocele(4/4 vs.3/4),sacrococcygeal hypoplasia(2/3 vs.0/3),syringomyelia(2/4 vs.0/4),caudal regression syndrome(1/1 vs.0/1),myelomeningocele(6/6 vs.3/6);for meningocele,tight filum terminale and sacrococcygeal teratoma,the diagnostic accuracy of prenatal ultrasound was the same as that of fetal MRI.For each type of fetal SNTDs,the manifestations of prenatal ultrasound and fetal MRI had their own characteristics.Conclusions Prenatal ultrasound and fetal MRI have different advantages in diagnosing fetal SNTDs.Fully understanding the characteristic prenatal imaging manifestations of SNTDs can improve the accuracy of prenatal diagnosis.

FetusUltrasonography,prenatalMagnetic resonance imagingPrenatal diagnosisSpinal neural tube defects

孙梦纯、尚爱加、李超超、高干、陶本章、汪汇、苏天崎

展开 >

解放军总医院第一医学中心神经外科医学部,北京 100853

南开大学医学院,天津 300071

天津医科大学,天津 300070

胎儿 超声检查,产前 磁共振成像 产前诊断 脊髓神经管畸形

国家重点研发计划首都卫生发展科研专项

2022YFC2703304CFH2022-2-5022

2024

中华神经外科杂志
中华医学会

中华神经外科杂志

CSTPCD北大核心
影响因子:1.107
ISSN:1001-2346
年,卷(期):2024.40(2)
  • 18