摘要
机房和配电室是电网的重要组成部分和电能传输的重要环节,对保证电网安全和企业、居民正常用电具有十分重要的意义.防止老鼠进入机房和配电室破坏电力设备,引发断电和火灾,是确保企业和居民安全用电的重要工作.从机房和配电室的结构特点出发,结合老鼠的行为习性,对机房和配电室如何防止老鼠入侵危害的管理措施与技术方法进行了探讨.
Abstract
The computer room and power distribution room are important parts of the power grid and an important link of power transmission,which is of great significance to ensure the security of the power grid and the normal power consumption of enterprises and residents.Preventing rats from entering the computer room and power distribution room to damage power equipment,causing power cuts and fires is an important task to ensure the safe use of electricity by enterprises and residents.Starting from the structural characteristics of the computer room and power distribution room,combined with the behavior habits of mice,this paper discusses the management measures and technical methods of how to prevent the invasion of rats in the computer room and power distribution room.
关键词
配电室/鼠类/危害/防控策略Key words
power distribution room/rodents/damage/prevention and control strategies引用本文复制引用