首页|天然气净化厂机房和配电室鼠害及其防控策略探讨

天然气净化厂机房和配电室鼠害及其防控策略探讨

Discussion on rodent infestation and prevention and control strategies in the computer room and power distribution room of natural gas purification plant

扫码查看
机房和配电室是电网的重要组成部分和电能传输的重要环节,对保证电网安全和企业、居民正常用电具有十分重要的意义.防止老鼠进入机房和配电室破坏电力设备,引发断电和火灾,是确保企业和居民安全用电的重要工作.从机房和配电室的结构特点出发,结合老鼠的行为习性,对机房和配电室如何防止老鼠入侵危害的管理措施与技术方法进行了探讨.
The computer room and power distribution room are important parts of the power grid and an important link of power transmission,which is of great significance to ensure the security of the power grid and the normal power consumption of enterprises and residents.Preventing rats from entering the computer room and power distribution room to damage power equipment,causing power cuts and fires is an important task to ensure the safe use of electricity by enterprises and residents.Starting from the structural characteristics of the computer room and power distribution room,combined with the behavior habits of mice,this paper discusses the management measures and technical methods of how to prevent the invasion of rats in the computer room and power distribution room.

power distribution roomrodentsdamageprevention and control strategies

慕凌、黄昱恺、刘进、叶富铭、权秋月

展开 >

重庆市天然气净化总厂,重庆 400021

配电室 鼠类 危害 防控策略

2024

中华卫生杀虫药械
南京军区疾病预防控制中心

中华卫生杀虫药械

CSTPCD
影响因子:0.566
ISSN:1671-2781
年,卷(期):2024.30(2)
  • 12