地下水电站厂房内的热湿环境对工作人员身体健康以及设备安全运行有着重要影响.针对贵州某水电站进行了全年 4 个典型季节的地下厂房内热湿环境现场测试,发现该水电站地下厂房主要洞室全年干球温度 10.2~26.7℃、相对湿度 44.0~94.5%;热湿环境状况总体较好,但部分季节、部分洞室存在空气相对湿度偏高,部分低温设备及管道壁面存在不同程度"结露"现象.通过对地下厂房热湿环境存在问题的理论分析,提出了针对性的通风除湿改进方案,可以为类似水电站地下厂房的热湿环境调控提供一定的工程参考.
The thermal environment of the underground powerhouse in hydropower station has a significant impact on the health of the staffs and the operation of the equipments.This paper presents on-site tests of thermal environment for four typical seasons throughout the year at a hydropower station in Guizhou.The results show the yearly air temperature is 10.2~26.7℃and the relative humidity is 44.0~94.5%for the main plants,which indicates the integral thermal environment is in good condition.However,some plants have the problem of high relative humidity in part seasons.Another problem is the dewing phenomenon on the low temperature equipments and pipes.The paper presents the improved plan for the ventilation based on the theoretical analysis of the thermal environment problems mentioned above.The conclusions can provide references for the thermal environment similar to the underground powerhouse in hydropower station.

Underground powerhouse of hydropower stationThermal environmentOn-site testingDewingDehumidification

陈极、罗禄堂、张文波、朱海鹏、李斌、肖益民

展开 >

贵州乌江水电开发有限责任公司东风发电厂 贵阳 550000

重庆大学 重庆 400000

中国电建集团中南勘测设计研究院有限公司 长沙 410014

水电站地下厂房 热湿环境 现场测试 结露 除湿

2024

制冷与空调(四川)
四川省制冷学会 西南交通大学

制冷与空调(四川)

CSTPCD
影响因子:0.475
ISSN:1671-6612
年,卷(期):2024.38(5)