首页|直升机灭火系统灭火剂浓度时间分布特性试验研究

直升机灭火系统灭火剂浓度时间分布特性试验研究

扫码查看
通过对直升机灭火系统灭火剂浓度扩散进行试验研究,分析了在不同单位体积通风量、不同灭火剂及不同压力状态下的灭火剂喷射后浓度分布特性.通过对时间特性和分布特性的试验研究,分析了单位体积通风量变化对灭火剂浓度维持时间的影响以及单位体积通风量变化对浓度变化率的影响,给出了单位体积通风量低于1.32 kg/(s·m3)时,应留有较大设计余量的措施.
Experiment Study on the Distribution Characteristics of Fire Extinguishing Agent Concentration in Helicopter Fire Extinguishing System
This article conducted experimental research on the concentration diffusion of fire extin-guishing agents in helicopter fire extinguishing systems,and analyzed the extinguishing agents sprayed under different unit volume ventilation,different fire extinguishing agents,and different pressure states.Through experimental research on time and distribution characteristics,the influence of unit volume ventilation on the maintenance time of fire extinguishing agent concentration and the influence of unit volume ventilation on concentration change rate were analyzed.Measures for leaving a large de-sign margin when the unit volume ventilation was less than 1.32 kg/(s·m3)were proposed.

fire extinguishing systemconcentration distributiondistribution characteristic

李松松、韩代春、吴燕燕、李春