首页|超声引导下不同浓度罗哌卡因腰方肌阻滞应用于剖宫产患者的效果

超声引导下不同浓度罗哌卡因腰方肌阻滞应用于剖宫产患者的效果

扫码查看
目的:探讨超声引导下不同浓度罗哌卡因腰方肌阻滞应用于剖宫产患者的效果。方法:选择 2020 年 1 月—2023 年 1 月厦门大学附属第一医院杏林分院收治的 100 例剖宫产患者,按照随机数表法分为A组(n=33)、B组(n=33)、C组(n=34),分别采用浓度为 0。250%、0。375%及 0。500%的罗哌卡因麻醉。观察三组麻醉相关指标、术后疼痛程度、镇痛药物使用情况及术后并发症。结果:术后 6 h、12 h、24 h、36 h,A组静息及运动状态下视觉模拟评分法(VAS)评分高于B组及C组,差异有统计学意义(P<0。05),而B组与C组静息及运动状态下VAS评分比较,差异无统计学意义(P>0。05)。A组静脉自控镇痛(PCIA)按压次数及舒芬太尼用量均高于B组及C组,差异有统计学意义(P<0。05),而B组与C组PCIA按压次数及舒芬太尼用量比较,差异无统计学意义(P>0。05)。C组不良反应总发生率高于B组及A组,差异有统计学意义(P<0。05);A组、B两组不良反应总发生率比较,差异无统计学意义(P>0。05)。三组镇痛总满意度比较,差异有统计学意义(P<0。05),且B组镇痛总满意度高于A组及C组,C组高于A组,差异有统计学意义(P<0。05)。结论:不同浓度罗哌卡因对剖宫产术均有较好的麻醉效果,其中 0。375%及 0。500%浓度的罗哌卡因镇痛效果更好,但 0。375%浓度罗哌卡因镇痛满意度及安全性更高。
Effect of Different Concentration of Ropivacaine Quadratus Lumborum Block under Ultrasound Guidance in Patients with Cesarean Section
Objective:To investigate the effect of different concentration of Ropivacaine quadratus lumborum block under ultrasound guidance in patients with cesarean section.Method:A total of 100 patients with cesarean section admitted to Xinglin Branch of the First Affiliated Hospital of Xiamen University from January 2020 to January 2023 were selected,and they were divided into group A(n=33),group B(n=33)and group C(n=34)according to random number table method,and they were anesthetized with Ropivacaine at 0.250%,0.375%and 0.500%,respectively.Anesthesia related indexes,postoperative pain degree,analgesic drug use and postoperative complications were observed among the three groups.Result:At 6 h,12 h,24 h,and 36 h after surgery,the visual analogue scale(VAS)scores in resting and exercise states of group A were higher than those of group B and group C,the differences were statistically significant(P<0.05);however,there were no statistically significant differences in VAS scores in resting and exercise states between group B and group C(P>0.05).The number of compressions for patient-controlled intravenous analgesia(PCIA)and the amount of Sufentanil used in group A were higher than those in group B and group C,and the differences were statistically significant(P<0.05);however,there were no statistically significant differences in the number of compressions for PCIA and the amount of Sufentanil used in between group B and group C(P>0.05).The total incidence of adverse reactions in group C were higher than those in group B and group A,and the differences were statistically significant(P<0.05);there was no statistically significant difference in the total incidence of adverse reactions between group A and group B(P>0.05).The total satisfaction with analgesia among the three groups were statistically significant(P<0.05),the total satisfaction with analgesia in group B were higher than those in group A and group C,and group C was higher than group A,the differences were statistically significant(P<0.05).Conclusion:Different concentrations of Ropivacaine have better anesthetic effect on cesarean section,among which 0.375%and 0.500%concentration of Ropivacaine have better analgesic effect,but 0.375%concentration of Ropivacaine has higher analgesic satisfaction and safety.

RopivacaineCesarean sectionSufentanilQuadratus lumborum block

龚赞辉、吴雅君

展开 >

厦门大学附属第一医院杏林分院 福建 厦门 361000

厦门市儿童医院

罗哌卡因 剖宫产 舒芬太尼 腰方肌阻滞

2024

中外医学研究
中国医院管理杂志社

中外医学研究

影响因子:1.149
ISSN:1674-6805
年,卷(期):2024.22(7)
  • 15