Abstract
The "barrel effect" in proton exchange membrane fuel cell (PEMFC) stacks is one of the important factors limiting its performance and lifetime. This paper systematically investigates the voltage consistency and local voltage consistency of open cathode air-cooled PEMFCs under different operating conditions through experimental tests, theoretical analysis, and the Entropy-Weighted TOPSIS comprehensive evaluation method. Based on the study of PEMFC voltage dispersion, the voltage deviation and proportion of the poor single cell are considered. Results show that side-cell groups have higher voltage variation coefficients than middle ones, caused by uneven hydrogen partial pressure, end water accumulation and asymmetric fan supply. The coefficient decreases by 19.02 % at 5 A compared with open circuit, as moderate current mitigates membrane dehydration and flooding. The overshoot and undershoot phenomena of the average voltage and voltage variation coefficient stem from the transient mismatch between reactant diffusion rate, reaction kinetics, and electrochemical reaction requirements. Appropriately increasing the fan speed and hydrogen inlet pressure is conducive to improving the voltage consistency of PEMFCs. In addition, the comprehensive evaluation results indicate that the optimal purge interval and purge duration for the open-cathode air-cooled PEMFC stack tested in this study are 10 s and 0.6 s respectively.