Abstract
This paper presents a single polarization curve calibration framework for reduced-order solid oxide fuel cell (SOFC) models. Two variants are calibrated: a model that considers only hydrogen (H_2) oxidation (H-ECM), and a model that includes carbon monoxide (CO) co-oxidation (HC-ECM). Six datasets are analyzed with 20 polarization curves covering hydrogen and syngas operation. The hydrogen cases show maximum absolute voltage errors of 14.3-71.5 mV, while the syngas cases show 4.2-134.9 mV and 5.1-95.5 mV for H-ECM and HC-ECM respectively. The fit quality is high, with a coefficient of determination (R~2) > 0.99 in 19 out of 29 total calibration cases. Including CO oxidation does not improve the single-curve fit systematically, and the parameters frequently reach the imposed bounds. Repeated calibrations show comparable polarization curves with different parameter sets, suggesting limited practical identifiability. When physically interpretable parameters are required, shared-parameter calibration is recommended.